Malfunctions; Malfunctions On Cooling System - Oprema PREMIX Serie Manual De Operación Y Mantenimiento

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 52
EN

Malfunctions on cooling system

Description
Compressor is not working
Compressor working all the time but
no ice bank
Motor agitator not working
20

MALFUNCTIONS

Possible reason
1. Full ice bank
2. Cooler not connected to power
supply
3. Connecting cable connector not
plugged in
4. To low voltage of power supply
5. Plug socket broken or connection
cable broken
6. Broken starting relay, starting
condenser or work condenser of
compressor
7. Broken thermostat or electro
installation
8. Broken compressor
9. Compressor protection activated
during overheating
1. To much dispense
2. Cooler is positioned on to warm
place or air flow is not sufficient
1. To low voltage
2. Broken motor agitator
3. Connection cable not connected or
broken
4. Connector on connection cable not
connected
Repair description
1. Thermostat is turning off
compressor when sufficient ice bank is
made. Compressor starts with work
again when there is no enough ice bank
2. Connect cooler to power supply
3. Connect connector
4. Minimal voltage for normal work is
208V
5. Call for service
6. Call for service
7. Call for service
8. Call for service
9. Call for service
1. Decrease dispense
2. Change the position of cooler or
clean condenser from dust
1.
Minimal voltage for normal work is
208V
2.
Call for service
3.
Call for service
4. Connect connector