6. Retrieval Mechanism:
Ensure that the retrieval mechanism and associated components are
working properly according to the operation instructions (see section 4.0 of this manual).
UNITS THAT DO NOT PASS INSPECTION OR HAVE BEEN SUBJECTED TO
THE FORCES OF ARRESTING A FALL OR AFFECTING A RESCUE
MUST BE REMOVED FROM SERVICE.
7.2 Maintenance
Basic care of all safety equipment will prolong the durable life of the unit and will contribute
toward the performance of its vital safety function.
Servicing
Servicing of the Miller MightEvac Self-Retracting Lifeline must only be carried out by Miller
Fall Protection or persons or entities authorized in writing by Miller Fall Protection. A record
log of all servicing and inspection dates for this device must be maintained. Only original Miller
replacement parts are approved for use in this device. Repairable devices must be returned
to our facilities or an approved service center whenever subjected to fall arresting forces for
physical inspection and recertification. Non-repairable devices that do not pass inspection
must be disposed of in a manner to prevent inadvertent further use. Contact your Miller
distributor for a return authorization number.
Miller self-retracting lifelines require no annual factory recertification.
[Note for CSA Approved Products: CSA Z259.2.2-98 requires Type 2 and Type 3 devices to be
returned to the manufacturer or an approved service agent no more than 2 years after the date of
manufacturer for inspection and maintenance and annually thereafter.]

Cleaning and Storage

Periodically clean the exterior of the device and wipe the lifeline using a damp cloth and mild
detergent. Towel dry. Store in a clean, dry location when not in use. The lifeline should be
fully retracted into the device when not in use.