CAUTION
Observe the following to avoid property damage:
• Confirm water pressure to water valve is between
20 and 120 pounds per square inch.
• Copper supply tubing must be routed where the
temperature is 55°F (13°C) or higher to prevent
freeze-ups.
• Start adaptor fitting and nuts by hand to avoid cross
threading. Tighten adaptor fitting and nuts with
pliers and wrenches. Do not overtighten.
• Check for water leaks and correct if necessary
before returning refrigerator to normal location, and
24 hours after connecting.
Important
• Before connecting water supply, contact a plumber to
connect copper tubing to household plumbing in
compliance with local codes and ordinances.
• DO NOT use self-piercing type or
Both reduce water flow, develop sediment build-up
more rapidly, and may cause leaks if repair is
attempted. The correct type of shut-off valve requires
a ¼" hole to be drilled on top or side (not bottom of
horizontal pipe) of water supply pipe prior to valve
attachment.
Materials Required
¼" O.D. (6 mm) flexible copper tubing. Length of copper
tubing must reach from water supply connection to water
valve inlet port on back of refrigerator plus an additional
8 ft. (2 m) of tubing for a service loop. A service loop will
allow refrigerator to be pulled away from the wall without
disconnecting tubing.
Procedure
1. Remove plastic cap from water valve inlet port.
2. Place brass nut and brass sleeve on copper tubing
(Brass nut and sleeve are found in literature packet).
Insert copper tubing into water valve inlet port.
Connect brass nut on copper tubing to water valve
inlet port. Start connection by hand then use a ½"
(13 mm) open end wrench. Make sure copper tubing
is secure by pulling on copper tubing.
3
/
" saddle valves!
16
Water valve inlet
port
Plastic cap
Water valve
inlet port
3. Create a service loop using extreme care to avoid
kinks. Secure copper tubing to refrigerator cabinet
with a "P" clamp.
4. Turn on water supply to refrigerator and check for
leaks. Correct any leaks at connection. Be careful
not to overtighten connection.
5. Proceed to Leveling Refrigerator for final refrigerator
placement.
6. Review Installation Checklist in Owner's Manual with
consumer.
6
"P" clamp
Copper tubing
Brass sleeve
Brass nut
Tabla de contenido