Problem
Dryer Will
Not Run
Lint in Load
Stains on Load Improper use of fabric softener
Items
Shrinking
Loads are
Wrinkled
Odors
Unusual
Sounds
42
42
Possible Cause
Power cord not firmly plugged
in.
Fuse blown or circuit
breaker tripped.
Using a regular fuse.
Dryer door not firmly closed.
START pad not pressed.
Cycle not selected.
Lint screen is clogged.
Improper sorting.
Load is too big or heavy.
Load is overdried.
Paper or tissue in pockets.
Pilling being mistaken for lint.
in washer.
Drying soiled items.
Overdrying.
Poor garment quality.
Manufacturer's care label
instructions not followed.
Overloading.
Overdrying.
Load left in dryer at the
end of cycle.
Painting, staining, or varnishing
has recently taken place in the
area where your dryer is located. the clothing and then dry it.
Gas leak
Clicking – gas valve clicking.
Thumping of rollers when
dryer has set.
Solution
Plug into a grounded 3 prong outlet.
Replace fuse or reset breaker.
Replace with a time-delay fuse.
Close dryer door tightly.
Press START pad.
Select cycle and press START pad.
Clean lint screen.
Sort lint givers from lint takers
and by color.
Dry smaller loads so lint can be
carried to the lint screen.
Use correct dryer settings for fabric.
Overdrying can cause lint-attracting
static (see "OPERATION").
Clean out pockets before drying.
Pilling (surface fuzz) is caused by
normal wear and laundering.
Use fabric softener sheets in dryer. Add
at beginning of cycle when load is cold.
Items need to be clean before
being dried.
Match dryer settings to fabric type
(see "OPERATION").
Check quality of garment before
purchasing.
Follow fabric care label instructions
carefully.
Dry smaller loads that can tumble freely.
Match dryer settings to fabric type
(see "OPERATION").
Remove load as soon as tumbling
stops.
Ventilate the area. When the odors or
fumes are gone from the area, re-wash
Turn off gas supply line. Leave your
house, then call your local gas
company.
Normal operation.
Thump will go away after 5 minutes
of drying.