MOBILE HOME EXHAUST
REQUIREMENTS
• The dryer must not be installed where
it can be exposed to water and/or
weather. Proper operation of dryer
cycles requires temperatures above
45°F (at lower temperatures, the
dryer may not shut off at the end of
automatic cycles and drying times
will be extended).
• Use at least the minimum installation
spacings described on page 12. This will
ensure you have an adequate clearance
for service and proper operation
including flow of combustion and ventila-
tion air, and that you have a sufficient
distance from combustible construction.
• Special provisions must be made for the
introduction of outside air into the dryer
when installed in a mobile home. The
area of any opening for the introduction
of outside air (such as a nearby window)
should be at least twice as large as the
dryer exhaust opening.
This dryer is suitable for mobile home
installations. The installation must
conform to the Manufactured Home Con-
struction and Safety Standard, Title 24
CFR, Part 3280 (formerly the Federal
Standard for Mobile Homes Construction
and Safety, Title 24, HUD Part 280).
• Dryer exhaust vent must not
be connected or secured with
screws or other
devices which
extend into the
interior of the
vent.
• A gas dryer
must be
exhausted
outdoors. The
exhaust vent
must be securely fastened to a
noncombustible portion of the
mobile home structure and must not
terminate beneath the mobile home.
For mobile home use, gas dryers must
be securely fastened to the floor. Order
Mobile Home Installation Kit 346764 from
your Sears store or Sears Service Cen-
ter. Kit includes the necessary fastening
hardware and detailed installation instruc-
tions. Exhaust system hardware
is also available through your Sears store
or Sears Service Center.
WARNING:
To reduce the risk
of fire, this appliance MUST BE
EXHAUSTED OUTDOORS.
13