Hazardous area
Class I/II/III, Division 1, Group A,B,C,D,E,F,G
or Class I, Zone 0/1 Group IIC
Intrinsically safe apparatus
entity parameters:
Vmax (Ui) ≥ Vt (Uo)
Imax (Ii)
≥ It (Io)
Pi ≥ Po
Ca ≥ C
+ Ci
cable
La ≥ L
+ Li
cable
The sum of capacitance and
inductance of cable and
intrinsic safe equipment must
be less or equal to Ca and La
Ex input
CH1 (terminal 42,43)
CH2 (terminal 52,53)
Vt (U
):
17.4 V
o
It (I
):
18.4 mA
o
P
:
80 mW
o
Lo/Ro
445 μH/Ω
IIC /
IIB /
Group A,B
Group C,E,F
C
/ C
0.3 μF
1.6 μF
a
o.
L
/ L
80 mH
250 mH
a
o.
U
:
10 V
i
I
:
30 mA
i
C
:
15 nF
i
1.7μH
L
i.
Revision date:
2009-08-24
Non Hazardous Area or
Class I, Division 2, Group A,B,C,D T4
or Class I, Zone 2 Group IIC T4
-20 ≤ Ta ≤ 60ºC
+
-
IIA /
Group D,G
8 μF
600 mH
Version Revision:
V2 R0
9113 - Product Version 9113-001
4501
44
43
CH1
42
41
54
53
CH2
52
51
9113
91 92 93 94 95
Power
Rail
Prepared by:
PB
9113QF01
34
33
32
31
14
13
12
11
(terminal 11,12,13,14)
(terminal 31,32,33,34)
(terminal 91,92,93,94,95)
U
: 253V, max 400Hz
m
Page: