2) GENERAL OUTLINE
The Clonix U-Link receiver is supplied by the manufacturer with stan-
dard settings. Any change must be made using the programmer with
built-in display or universal handheld programmer. Fully supports
U-LINK protocol.
Its main features are:
- Built-in rolling-code or fixed code radio receiver with transmitter cloning
to manage up to 2048 codes.
- 3 input slots managed to house up to 3 boards with U-Link protocol.
- 2 or 3 relays/outputs settable as non-latching, latching, timed and panic
managed.
- Password protected receiver.
The Clonix U-Link receiver combines the characteristics of utmost safety
in copying variable code (rolling code) coding with the convenience of
carrying out transmitter "cloning" operations thanks to an exclusive system.
Cloning a transmitter means creating a transmitter which can be included
automatically within the list of the transmitters memorised in the recei-
ver, either as an addition or as a replacement of a particular transmitter.
Therefore it will be possible to remotely program a large number of
additional transmitters, or for example, replacement transmitters for
those which have been lost, without making changes directly to the
receiver. Cloning by replacement is used to create a new transmitter
which takes the place of the one previously memorised in the receiver;
in this way the lost transmitter is removed from the memory and will
no longer be usable
When coding safety is not a decisive factor, the receiver allows you to
carry out fixed code additional cloning, which although abandoning the
variable code, provides a high number of coding combinations.
Using clones when there is more than one receiver (as in the case of
communal buildings),
and especially when a distinction is to be made between clones to be
added to or replaced in individual or collective receivers, could turn out
to be rather difficult. The receiver cloning system for communal buildings
makes it particularly easy to solve the problem of clone storage for up
to 250 individual receivers.
Entrance control is managed by relays. Two relays in N.O. configuration
are available in the 2E version while there are 3 relays in the UNI version,
two with N.O contact while the third has N.O. or N.C. contact based on
the configuration the user sets with the jumper.
3) TECHNICAL SPECIFICATIONS
CLONIX UNI AC U-LINK 230
Power supply
CLONIX 2E AC U-LINK 230
Operating temperature range
Protection rating
Antenna impedance
OUT 1 , OUT 2 , OUT 3 ***
Max. n° of radio transmitters that can
be memorized
N° of combinations
Dielectric rigidity
Built-in Rolling-Code radio-receiver
Setting of parameters and options
(*) other voltages to order
(**) only guaranteed when using the appropriate cable glands
(***) three outputs only in the UNI
4) TERMINAL BOARD WIRING Fig. B
WARNINGS - When performing wiring and installation, refer to the
standards in force and, whatever the case, apply good practice principles.
Terminal
Definition
L
N
20
21
22
23
24
25
Y
#
* only on CLONIX UNI AC U-LINK 230.
INSTALLATION MANUAL
220-230V~ 50/60 Hz*
-10/+60°C
IP 55**
50 Ohm (Rg58)
NO contact
(120V~/1A, 24V
/max 1A)
2048
4 billion
3750V~ for 1 minute
frequency 433.92MHz
Universal handheld programmer/
LCD display
LINE
See Par. 3) Technical Specifications Table
NEUTRAL
OUT 1 configurable output - Default setting NON-LATCHINg.
OUT 1
NON-LATCHINg; LATCHINg; ANTIPANIC. Refer to the OUTPUT CONFIgURATION table.
OUT 2 configurable output - Default setting NON-LATCHINg.
OUT 2
NON-LATCHINg; LATCHINg; ANTIPANIC. Refer to the OUTPUT CONFIgURATION table.
OUT 3 configurable output - Default setting NON-LATCHINg.
OUT 3*
NON-LATCHINg; LATCHINg; ANTIPANIC. Refer to the OUTPUT CONFIgURATION table.
Antenna input.
ANTENNA
Use an antenna tuned to 433MHz. Use Rg58 coax cable to connect the Antenna and Receiver. Metal bodies close to the an-
tenna can interfere with radio reception. If the transmitter's range is limited, move the antenna to a more suitable position.
SHIELD
Wires carrying different voltages must be kept physically separate from
each other, or they must be suitably insulated with at least 1mm of ad-
ditional insulation.
Wires must be secured with additional fastening near the terminals,
using devices such as cable clamps.
All connecting cables must be kept far enough away from the dissipater.
WARNING! For connection to the mains power supply, use a multicore
cable with a cross-sectional area of at least 3x1.5mm
provided for by the regulations in force.
5) CALLING UP MENUS: FIG. 1
5.1) RADIO MENU (radio) (RADIO TABLE "A")
- IMPORTANT NOTE: THE FIRST TRANSMITTER MEMORIZED MUST
BE IDENTIFIED BY ATTACHING THE KEY LABEL (MASTER).
In the event of manual programming, the first transmitter assigns the
RECEIVER'S KEY CODE: this code is required to subsequently clone the
radio transmitters.
The Clonix built-in on-board receiver also has a number of important advanced
features:
• Cloning of master transmitter (rolling code or fixed code).
• Cloning to replace transmitters already entered in receiver.
• Transmitter database management.
• Receiver community management.
To use these advanced features, refer to the universal handheld
programmer's instructions and to the general receiver programming guide.
5.2) OUTPUT CONFIGURATION MENU (OUTPUTS) (OUTPUT TABLE "B")
5.3) LOGIC MENU (LOGIC) (LOGIC TABLE "C")
5.4) SLOTS CONFIGURATION MENU (conf. s lots) (INPUT TABLE "D")
5.5) MENU DEFAULT (default)
Riporta la centrale ai valori preimpostati dei DEFAULT.
5.6) MENU LINGUA (lingua)
Consente di impostare la lingua del programmatore a display.
5.7) STATISTICS MENU (stat)
Displays the board version and number of saved transmitters.
5.8) PASSWORD MENU (PASSWORD)
Used to set a password for the board's wireless programming via the
U-link network.
With "PROTECTION LEVEL" logic set to 1,2,3,4, the password is required
to access the programming menus. After 10 consecutive failed attempts
to log in, you will need to wait 3 minutes before trying again. During
this time, whenever an attempt is made to log in, the display will read
"BLOC". The default password is 1234.
6) CONNECTION WITH EXPANSION BOARDS AND UNIVERSAL HAND-
HELD PROGRAMMER VERSION> V1.40 (Fig. D) Refer to specific manual.
7) RESTORING FACTORY SETTINGS Fig. D
WARNING: this operation will restore the control unit's factory
settings and all transmitters stored in its memory will be deleted.
- Cut off power to the board.
- Press the +, - and OK keys together.
- Switch on the board's power.
- The display will read RST; confirm within 3 sec. by pressing the OK key.
- Wait for the procedure to finish.
Description
of the kind
2
15
CLONIX U-LINK