WARNING: FUEL (GAS) BURNING RANGES MUST BE VENTED OUTDOORS USING, AT MINIMUM, METAL DUCTWORK AND RANGE HOODS
OF SUFFICIENT CAPACITY . Follow your fuel burning equipment manufacturer's guidelines, as well as, all applicable safety standards
published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning
Engineers (ASHRAE), and your local code authorities .
REMOVING THE ELECTRICAL KNOCK-OUT HOLE
WARNING:
Always wear safety goggles and gloves during
installation .
-
Choose the appropriate electrical knock-out hole to remove for your
installation type . Use the top hole (1) if your electrical supply is in
the cabinet and the back hole (2) if your electrical supply is on the
wall below the cabinet (refer to Fig . 9) .
-
Use a hammer and a flathead screwdriver to gently punch out the
electrical knock-out hole.
-
Use an approved strain relief to ensure the knock out hole does not
damage the insulation of the the electrical supply cable .
Fig . 9
INSTALLING THE DAMPER
NOTE:
Only install the damper if you are using a venting system that does not already have
a damper. If this hood replaces an existing unit, the location of the air exhaust can
vary from one manufacturer to another. Ensure that the damper fits in the existing
opening before installing.
-
The damper and the adapter are located inside the range hood . To
access these parts, remove the bottom panel (K) if you have not
previously done so (see Fig . 12) .
-
Choose to install the damper (C) either in the top
position (3A & B) for top venting or in the back position (5)
for back venting . Adapter (D) is used for top venting only and
installs in position 3A and 4 .
-
Attach damper (C) or adapter (D) over chosen knockout opening .
Make sure the damper pivot is oriented on top such that the
damper stays closed when not in use .
-
Secure the damper (C) or adapter (D) to the range hood (A) with the
short tapping screws (BB) .
-
Seal the damper (C) or adapter (D) to the range hood (A) on all four
sides with duct tape .
QR272S / QR272BS
REMOVING THE VENTING HOLE
-
Choose the venting hole to remove for your installation type . Use
the top holes (3 & 4) for a top venting installation and the back
hole (5) for a back venting installation . See Installing the damper
section for more details .
-
Carefully remove the cover (3, 4 or 5) of the appropriate venting
hole using a flat head screwdriver or needle nose pliers (refer Fig.
10) . Be careful not to leave any debris inside the range hood (A) .
5
Fig . 10
Fig . 12
3B
3A
3B
3A
10
Fig . 11
K
Fig . 13
C
D