Commissioning
Complete system
Slowly pressurize the complete system. This will prevent uncontrolled
S
movements from occurring.
For slow start−up pressurization, use safety start−up valve type HEL−...
or HEM−... .
Individual unit
Warning
S Make sure that:
nobody can place his/her hand in the positioning range of the handling
module
there are no objects in the path of the moveable mass
there is no tubing in the path.
Protect the area e.g. by means of a cover or screen.
Please note
The operating conditions for the setting procedure (operating pressure,
ambient temperature) must be identical with those in continuous operation.
Otherwise there is a danger of the handling module being overloaded.
Please note
S Handle the shock absorber with care so that the thread, the piston rod and
the outer cylinder are not damaged.
S Make sure that the shock absorbers are screwed in completely and locked
(as supplied from the factory). If the shock absorbers are not screwed in
completely, the cushioning effect will be considerably reduced (reduced
cushioning stroke).