UNO
R
If the appliance is placed near walls, dividers, kitchen
cabinets, decorated edges, etc., it is recommended
that this be of non combustible material.
Otherwise, they must be coated with non combustible
thermal insulating material and you must be very
respectful of the fire prevention standards.
3.4
REMOVE THE PROTECTIVE FILM
Carefully remove all the protective film from the
external walls of the appliance. Pay attention not to
leave any rest of glue on the sides.
If there should be any residue, please remove it with
an appropriate solvent.
4.
INSTALLATION
4.1 – ELECTRICAL CONNECTION
4.2 – WATER CONNECTION
4.1 ELECTRICAL CONNECTION
a- The connection to the electrical power supply system
must be done by qualified personnel according to
the standard in force. The installer is responsable for
a correct electrical connection and for security rules
observance.
Before connecting the appliance, make yourself sure
that the voltage and the frequency correspond to
those stated on the data plate of the appliance. The
appliance must be placed so that the connection plug
to the network can be easily reached.
In case of ovens equipped with cable without plug, it
is necessary to place an omni-polar switch between
the appliance and the network , easily accessible after
installation. The contacts of this switch must have a
minimum opening distance of 3 mm (overvoltage
category) and the switch must have an appropriate
carrying capacity.
It is suggested to use a differential magneto-thermal
switch.
When the appliance is working, the power supply
voltage must not diverge from the value of the nominal
voltage, written on the technical data plate, by more
than ± 10%.
b- The appliance must be connected to the ground line of
the network.
Moreover, the appliance must be included in an
equipotential system whose efficiency
must be properly checked according
to the current law. This connection
must be done between the different
appliances using the terminal marked
with the symbol:
The equipotential conductor must have
a minimum section of 10 mm
ENGLISH
4
.
2
POWER SUPPLY CONNECTION
1-
Ovens equipped with cordset and Schuko
plug (single phase 230V): is sufficient
to insert the plug in the proper socket
(the socket must be suitable for the plug
assembled in the oven)
2-
Ovens equipped with cordset (three phases
400V + Neutral): these ovens are equipped
with electrical cord with 5 conductors: it
is necessary to connect the proper three-
phase 5 poles plugi with suitable capacity
or you can connect the cord directly to the
electrical panel.
In those ovens equipped with a cord with 5 conductors
it is possible to substitute the power cord to adapt
the appliance to the available type of current.
Replacement of electric supply cable (in case of
damage or change of electric connection) has to be
done by authorized technical assistance service or
anyway by someone with similar qualification.
To substitute the power cord proceed as follows:
-
Open the cover of the terminal board
levering the two lateral small wings with a
proper screw-driver (1)
-
Unscrew the screws that lock the conductors (2)
-
Unscrew the screw that locks the cordstopper (3)
-
Remove the supplied cord
-
Connect the conductors that you would like
to use according to the chosen connection
drawing; be sure to fix properly the screws of
the clamps.
-
Block the cord using the proper cordstopper
-
Close the cover of the terminal board.
ENGLISH