15 Fix the flanges on the front of the cabinet,
using the screws supplied.
N.B.Check that there are no gaps between the joined parts.
16 Replace the back panels.
N.B.Check door opening. Once the doors are opened, they should close again even without the help of
the spring closer.
The spring closer is factory prepared.
If necessary, adjust the spring load as follows:
a - Insert the spring-loading spanner (A) into
one of the holes of the lower pin.
b - Rotate the pin anti-clockwise to remove the
safety pin (B).
c - Rotate the lower pin clockwise and position
the safety pin in the next hole.
(B)
17 Assemble the PVC profile on the casing.
Assemble the casing.