Spray Gun Lubrication - DeVilbiss TEKNA PROLITE 703536 Manual De Instrucciones

Ocultar thumbs Ver también para TEKNA PROLITE 703536:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

TB-1014-B
INSTALLATION
For maximum transfer efficiency, do not use more pressure than
is necessary to atomise the material being applied.
1.
Connect the gun to a clean, moisture and oil free air
supply using a hose size of at least 8 mm (5/16") I.D. hose.
Do not use 6 mm I.D. hose (8 m x 6 mm hose at 510 LPM
has a pressure loss of 1.8 bar. 8 m x 8 mm hose at 510 LPM
has a pressure loss of 0.6 bar. [Do not use 1/4" I.D. hose
(25' x 1/4" hose at 18 CFM has a pressure loss of 25 psi.
25' x 5/16" hose at 18 CFM has a pressure loss of 8 psi).]
Depending on hose length, larger I.D. hose may be required.
When gun is triggered on, adjust inlet air pressure
(for recommended pressures see Chart 1 under Parts
Replacement) at the gun inlet. (Pressure gauge shown under
Accessories is recommended for this). Do not use more
pressure than is necessary to atomise the material being
applied. Excess pressure will create additional overspray and
reduce transfer efficiency.
If quick connects are required, use only high flow quick con-
nects approved for HVLP use. Other types will not flow enough
air for proper gun operation.
If an air adjusting valve is used at the gun inlet, use a DeVilbiss
air adjusting valve. Some competitive adjusting valves have
significant pressure drop that can adversely affect spray per-
formance. DeVilbiss air adjusting valves have minimal pressure
drop.
2.
Attach the fluid supply hose to the fluid inlet connector.
Protective coating and rust inhibitors have been used
to keep the gun in good condition prior to shipment.
Before using the gun, flush it with solvents so that these
materials will be removed from fluid passages.
OPERATION
1.
Mix coating material to manufacturer's instructions and strain
material.
2.
Fill the pressure cup with the required amount of material.
DO NOT OVERFILL.
3.
Attach Cup Lid.
4.
Turn fluid adjusting knob (28) clockwise to prevent fluid
needle movement.
5.
Turn spreader valve adjusting knob (16) counter clockwise to
fully open.
6.
Trigger gun on and adjust inlet air pressure (for
recommended figures see Chart 1 under Parts Replacement)
at the gun inlet. (Pressure gauge shown under Accessories is
recommended for this).
7.
Turn fluid adjusting knob (28) counter clockwise until first
thread shows and turn on the supply air to the pressure cup.
8.
Test spray. If the finish is too dry, reduce airflow by reducing
air inlet pressure.
6
NOTE
NOTE
NOTE
NOTE
9.
If finish is too wet, reduce fluid flow by turning fluid adjusting
knob (28) clockwise. If atomisation is too coarse, increase inlet
air pressure. If too fine, reduce inlet pressure.
10. The pattern size can be reduced by turning spreader valve
adjusting knob (16) clockwise.
11. Hold gun perpendicular to surface being sprayed. Arcing
or tilting may result in uneven coating.
12. The recommended spray distance is 150-200 mm (6"–8").
13. Spray edges first. Overlap each stroke a minimum of 75%. Move
gun at a constant speed.
14. Always turn off air supply and relieve pressure when gun is not
in use.
PREVENTIVE MAINTENANCE & CLEANING
To clean air cap and fluid nozzle, brush exterior with a stiff bristle
brush. If necessary to clean cap holes, use a broom straw or
toothpick if possible. If a wire or hard instrument is used, extreme
care must be used to prevent scratching or burring of the holes which
will cause a distorted spray pattern.
To clean fluid passages, remove fluid supply hose, then flush with a
suitable solvent. Wipe gun exterior with a solvent dampened cloth.
Never completely immerse in solvent as this is detrimental to the
lubricants and packings.
When replacing the fluid nozzle or fluid needle, replace both
at the same time. Using worn parts can cause fluid leakage.
See page 11, Chart 2. Also, replace the needle packing at this
time. Lightly lubricate the threads of the fluid nozzle before
reassembling. Torque to 18–20 Nm (13–15 ft-lbs). Do not over
tighten the fluid nozzle.
To prevent damage to fluid nozzle (8) or fluid needle (24), be
sure to either 1) pull the trigger and hold while tightening or
loosening the fluid nozzle, or 2) remove fluid adjusting knob (28)
to relieve spring pressure against needle collar.

SPRAY GUN LUBRICATION

Daily, apply a drop of spray gun lubricant at trigger stud (40). The
shank of fluid needle (24) where it enters packing nut (36) should
also be oiled. Fluid needle packing (34) should be lubricated
periodically. Make sure spray head (9) and air cap retaining ring (1)
threads are clean and free of foreign matter. Before assembling air
cap retaining ring to spray head, clean the threads thoroughly, then
add two drops of spray gun lubricant to threads. Fluid needle spring
(25) and air valve spring (21) should
be coated with a very light grease,
making sure that any excess grease
will not clog the air passages.
Points of Lubrication
A.
Trigger Points
B.
Packing
C.
Adjusting Knobs
D.
Air Cap Retaining Ring Threads
NOTE
CAUTION
D
A
C
B
Tabla de contenido
loading

Este manual también es adecuado para:

Tekna pro lite

Tabla de contenido