Features
• Easy installation with strip terminal
• Tight regulation: 0.05% Line; 0.05% Load
• Full Output Ratings to +50 o C
• Built in OVP on 5 Volt Outputs
• OVP Option for 12V, 15V and 24V
• Foldback Current Limiting Overload Protection
with Automatic Recovery
General Specifications
Voltage/Current Ratings
Model Numbers
SLS-12-051T
SLS-15-045T
SLS-24-036T
SLS-05-090-1T
0 to +50 o C (Derate to 40% at +70 o C)
Operating Temperature Range
+/- 0.01% / o C
Temperature Coefficient (Typical)
Stability
Within +/- 0.05% (24 hours after warm-up)
Vibration
Per MIL-STD-810C, Method 514
Shock
Per MIL-STD-810C, Method 516
EMI/RFI
Linear power supplies have inherently low conducted and radiated noise levels.
For most system applications, these power supplies will meet the requirements
of FCC Class "B" and VDE 0871 for Class "B" equipment without additional
noise filtering.
Cooling
Forced air. 20 CFM required for full rating Derate 30% for convection cooling.
Multi Input (all units)
100/120/220/230/240 VAC selectable +/- 10% except 230 VAC is +15%, -6%
Frequency Range
47-63 Hz (Typical is 60 Hz. Derate output 10% at 50 Hz)
Transient Response Time
50 µ at 50% load changes for outputs rated up to 6A
100 µ at 50% load changes for outputs rated 6A and over.
Fuse Requirements
Units are not fused internally. For safe operation, user must provide input line
fuse as per values given in table.
Line Regulation
0.05% for +/- 10% change
Load Regulation
0.05% for 50% change
Ripple
3.0 mV maximum peak-to-peak
DC Output Adjustment Range
+/- 5% minimum (Check Voltage & Current ADJ Placement Diagrams)
Overvoltage Protection
All 5 volt outputs include built-in OVP as standard (setting is 6.2 V +/- 0.4 V).
OVP is optionally available on other outputs.
Remote Sensing
All units listed have remote sensing capability.
Overload Protection
125 to 150% foldback current limit
Linear Open Frame DC Power Supplies
Silver Line Instruction Manual
Models: SLS-12-051T, SLS-15-045T,
SLS-24-036T, SLS-05-090-1T
• Multi-Tap AC Inputs
• 100% Four-Hour Burn-in
• Limited Warranty for two years
• UL Recognized
• CSA Certified
• CE Marked
• CB Certified
Output
12 V / 5.1 A
15 V / 4.5 A
24 V / 3.6 A
5 V / 9.0 A
Input Specifications
Output Specifications
Input AC Connections (See Case C)
For use
at:
Connect
100 VAC
1-3, 2-4
120 VAC*
1-3, 2-4
220 VAC
2-3
230 VAC
2-3
240 VAC
2-3
*Note: Unit is shipped for 120V input from factory.
**Primary Fuse for SLS-24-036T
Mechanical Dimensions: Inches (mm)
Top View
7.00" (178)
.38" (9.6)
6.250" (158.8)
AC INPUT/DC OUTPUT
Please
See
Voltage
&
Current
ADJ
Placement
Diagrams
.50" (12.7)
OVP (OPTIONAL)
.50" (12.9)
.75" (19.1)
PEM NUT HOLES
8-32 MTG (4 PLACES)
WEIGHT: 7.28 LBS.
(3.3 KG)
Case C
Note: T he DC output can be adjusted with V. ADJ.
I. LIM is factory set on all models and should not be adjusted by users.
Application Note: U ser needs to provide earth ground to power supply with either solder to Tab or using washer and nut assembly.
The SLS power supply is shipped from the factory with metal shorting straps connected between the + OUT and + S
terminals and the (-) OUT and (-) S terminals. This strapping configuration allows the output of the SLS to be taken
from either pair of terminals. This is the standard configuration.
The remote sense feature is enabled by removing the shorting straps and connecting the individual OUT and S
terminals to the appropriate points of the load. If an OVP circuit is used it should be connected to the + OUT and (-)
OUT terminals. The OVP should never be connected to the + S, - S terminals without the use of the shorting straps.
In all cases it is critical that the terminal screws be firmly tightened.
Contact Technical Services at 1-800-377-4384 or
[email protected] with any questions.
Visit our website at www.solaheviduty.com
Apply AC to:
Primary Fuse
Primary Fuse**
1 & 5
1.6A / 125V
1 & 4
1.6A / 125V
1 & 5
0.8A / 250V
1 & 4
0.8A / 250V
1 & 4
0.8A / 250V
Voltage & Current
ADJ Placement
Diagrams
1.248" (31.7)
.75" (19.1)
R11
.551" (14)
V. ADJ
MAX
SLS-12-051T
SLS-24-036T
188"
°
MTG HOLES (12 PLACES)
(4.8)
R11
V. ADJ
SLS-15-045T
5
1
3
2
4
R13
V. ADJ
Case C
SLS-05-090-1T
2A/125V
2A/125V
1A/250V
1A/250V
1A/250V
R5
I.LIM
R5
I.LIM
R6
I.LIM