Emerson SLD-12-1010-12T Manual De Instrucciones
Ocultar thumbs Ver también para SLD-12-1010-12T:
Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

Features
• Easy installation with strip terminal
• Output adjustable from 12V to 15V
• Tight regulation: 0.05% Line; 0.05% Load
• Full Output Ratings to +50
o
C
• OVP Option for 12V and 15V.
• Foldback Current Limiting Overload Protection with
Automatic Recovery
General Specifications
Voltage/Current Ratings
Model Number
SLD-12-1010-12T
+12V/1.0A or +15V/0.8A
*Outputs are tied common
Operating Temperature Range
0 to +50
o
Temperature Coefficient (Typical)
+/- 0.01% /
Stability
Within +/- 0.05% (For 24 hours after warm-up)
Vibration
Per MIL-STD-810C, Method 514
Shock
Per MIL-STD-810C, Method 516
Linear power supplies have inherently low conducted and radiated noise levels.
EMI/RFI
For most system applications, these power supplies will meet the requirements
of FCC Class "B" and VDE 0871 for Class "B" equipment without additional
noise filtering.
Forced air. 20 CFM required for full rating Derate 30% for convection cooling.
Cooling
Input Specifications
100/120/220/230/240 VAC selectable +/- 10% except 230 VAC is +15%, -6%
Multi Input (all units)
Frequency Range
47-63 Hz (Typical is 60 Hz. Derate output 10% at 50 Hz)
50 µsec at 50% load change
Transient Response Time
Fuse Requirements
Units are not fused internally. For safe operation, user must provide input line
fuse as per values given in table.
Output Specifications
0.05% for +/- 10% change
Line Regulation
0.05% for 50% change
Load Regulation
3.0 nV maximum peak-to-peak
Ripple
DC Output Adjustment Range
+/- 5% minimum
Overvoltage Protection
OVP is optionally available
Overload Protection
125 to 150% foldback current limit
Contact Technical Services at 1-800-377-4384 or [email protected] with any questions.
Visit our website at www.solaheviduty.com
Linear Open Frame DC Power Supplies
Silver Line Instruction Manual
Model: SLD-12-1010-12T
• Multi-Tap AC Inputs
• 100% Four-Hour Burn-in
• Please see enclosed "Terms & Conditions and
Sales & Policies & Procedures"
• UL Recognized
• CSA Certified
Output 1
Output 2
-12V/1.0A or -15V/0.8A
C (Derate to 40% at +70
o
C)
C
o
Output Adjustment
Step 1:
Check the input AC connections
Step 2:
Connect the AC input according to the table below.
Step 3:
Use VR6 V.ADJ to adjust +V. Adj. to +15V or +12V
Step 4:
Use VR4 V.ADJ to adjust -V. Adj. to -15V or -12V
Input AC Connections
For use
at:
Connect
100 VAC
1-3, 2-4
120 VAC*
1-3, 2-4
220 VAC
2-3
230 VAC
2-3
240 VAC
2-3
*Note: Unit is shipped for 120V input from factory.
Mechanical Dimensions: inches (mm)
4.00 " ( 102)
. 25" (6.5 )
3.375" (86)
VR4
V.ADJ
VR6
V.ADJ
OVP
(OPTIONAL )
.50" (12.5)
. 75" ( 19)
Note: I. LIM is factory set and should not be adjusted by users.
Application Note: User needs to provide earth ground to power supply with either solder to Tab or using washer and
nut assembly.
Contact Technical Services at 1-800-377-4384 or [email protected] with any questions.
Visit our website at www.solaheviduty.com
Apply AC to:
Primary Fuse
1 & 5
0.63A/125V
1 & 4
0.63A/125V
1 & 5
0.315A/250V
1 & 4
0.315A/250V
1 & 4
0.315A/250V
.75" ( 19)
. 45" (11.5)
VR3
I.LIM
VR5
I.LIM
PEM NUT HOLES
.188 "
6-32 MTG (2 PLACES)
(4.8 )
°
MTG HOLES
(6 PLACES)
MAX WEIGHT:
2.21 LBS
(1 KG )
Case H1
Case H1
-12
COM
+12
4
2
3
1
5
Tabla de contenido
loading

Resumen de contenidos para Emerson SLD-12-1010-12T

  • Página 1 Linear Open Frame DC Power Supplies Output Adjustment Silver Line Instruction Manual Step 1: Check the input AC connections Model: SLD-12-1010-12T Step 2: Connect the AC input according to the table below. Step 3: Use VR6 V.ADJ to adjust +V. Adj. to +15V or +12V Step 4: Use VR4 V.ADJ to adjust -V.
  • Página 2: Especificaciones

    Múltiple Manual de la Instrucción Dé un paso 2: Conecte a la entrada de C.A. según posponer abajo. Modelo: SLD-12-1010-12T Dé un paso 3: Utilice VR6 V.ADJ para ajustar +V. Adj. to +15V or +12V Dé un paso 4: Utilice VR4 V.ADJ para ajustar -V. Adj. to -15V or -12V Características...
  • Página 3: General Specifications

    Linear Open Frame DC Power Supplies Output Adjustment Silver Line Instruction Manual Step 1: Check the input AC connections Model: SLD-12-1818-12T Step 2: Connect the AC input according to the table below. Step 3: Use VR6 to adjust +V. Adj. to +15V or +12V. Step 4: Use VR4 to adjust -V.
  • Página 4 Serie SL - Lineales de Salida Sencilla & El Ajuste de Salida Dé un paso 1: Verifica las conexiones de entrada de C.A. Múltiple Manual de la Instrucción Modelo: SLD-12-1818-12T Dé un paso 2: Conecte a la entrada de C.A. según posponer abajo. Dé...
  • Página 5 Linear Open Frame DC Power Supplies Output Adjustment Step 1: Check the input AC connections Silver Line Instruction Manual Step 2: Connect the AC input according to the table below. Model: SLD-12-3015-05T Step 3: Use VR2 to adjust +V. Adj. to +5V. Step 4: Use VR4 to adjust +V.
  • Página 6 Serie SL - Lineales de Salida Sencilla & El Ajuste de Salida Dé un paso 1: Verifica las conexiones de entrada de C.A. Múltiple Manual de la Instrucción Dé un paso 2: Conecte a la entrada de C.A. según posponer abajo. Modelo: SLD-12-3015-05T Dé...
  • Página 7 Linear Open Frame DC Power Supplies Input AC Connections Silver Line Instruction Manual For use Connect Apply AC to: Primary Fuse Model: SLD-12-3434-12T 100 VAC 1-3, 2-4 1 & 5 2.5A / 125V 120 VAC 1-3, 2-4 1 & 4 2.5A / 125V Features 220 VAC 1 & 5 1.25A / 250V • Easy installation with strip terminal • Multi-Tap AC Inputs 230 VAC 1 & 4 1.25A / 250V • Tight regulation: 0.05% Line; 0.05% Load...
  • Página 8: Características

    Serie SL - Lineales de Salida Sencilla & Entrada AC Conexiones Múltiple Manual de la Instrucción Para el uso en: Conecte Aplique AC a: El fusible primario Modelo: SLD-12-3434-12T 100 VAC 1-3, 2-4 1 & 5 2.5A / 125V 120 VAC* 1-3, 2-4 1 & 4 2.5A / 125V Características 220 VAC 1 & 5 1.25A / 250V • Terminales de conexión fáciles de instalar.
  • Página 9 Linear Open Frame DC Power Supplies Output Adjustment Step 1: Check the input AC connections Silver Line Instruction Manual Step 2: Connect the AC input according to the table below. Model: SLD-12-6034-05T Step 3: Use VR2 to adjust +V. Adj. to +5V. Step 4: Use VR4 to adjust +V.
  • Página 10 Serie SL - Lineales de Salida Sencilla & El Ajuste de Salida Dé un paso 1: Verifica las conexiones de entrada de C.A. Múltiple Manual de la Instrucción Dé un paso 2: Conecte a la entrada de C.A. según posponer abajo. Modelo: SLD-12-6034-05T Dé...
  • Página 11 Linear Open Frame DC Power Supplies Silver Line Instruction Manual Model: SLD-15-3030-15T Input AC Connections For use Connect Apply AC to: Primary Fuse Features 100 VAC 1-3, 2-4 1 & 5 2.5A / 125V • Easy installation with strip terminal •...
  • Página 12 Serie SL - Lineales de Salida Sencilla & Múltiple Manual de la Instrucción Modelo: SLD-15-3030-15T Entrada AC Conexiones Para el uso en: Conecte Aplique AC a: El fusible primario Características 100 VAC 1-3, 2-4 1 & 5 2.5A / 125V •...
  • Página 13 Silver Line Overvoltage: • Your load is now protected against an overvoltage condition that could destroy the load. Protection Option (OVP) • Should you experience a situation where the OVP triggers, remove input power! Check for Model:SLO-12-000-1 any failures. Instruction Manual •...
  • Página 14 Opción de Protección contra Sobretensiones Reenergice la fuente de alimentación y ajuste el voltaje de salida a la capacidad nominal de voltaje. El nivel de disparo de la OVP ahora está establecido. Quizá desee fijar en posición el potenciómetro del (OVP) para la Línea Silver OVP con un esmalte de grado eléctrico, como glyptol.
  • Página 15 Silver Line Overvoltage: • Your load is now protected against an overvoltage condition that could destroy the load. Protection Option (OVP) • Should you experience a situation where the OVP triggers, remove input power! Check for Model:SLO-12-000-TB any failures. Instruction Manual •...
  • Página 16: Voltajes De Disparador Recomendados

    Opción de Protección contra Sobretensiones Reenergice la fuente de alimentación y ajuste el voltaje de salida a la capacidad nominal de voltaje. El nivel de disparo de la OVP ahora está establecido. Quizá desee fijar en posición el potenciómetro del (OVP) para la Línea Silver OVP con un esmalte de grado eléctrico, como glyptol.
  • Página 17 Linear Open Frame DC Power Supplies Installation Step 1: Check the input AC connections Silver Line Instruction Manual Step 2: Connect the AC input according to table below. Models: SLS-05-030-1T, SLS-12-017T, Note: SLS-12-017T can be set to a +12V to +15V range by adjusting R9 V. ADJ. SLS-24-012T Features •...
  • Página 18: Serie Sl - Lineales De Salida Sencilla & Múltiple Manual De La Instrucción

    Serie SL - Lineales de Salida Sencilla & Instalación Dé un paso 1: Verifica las conexiones de entrada de C.A. Múltiple Manual de la Instrucción Dé un paso 2: Conecte a la entrada de C.A. según posponer abajo. Modelos: SLS-05-030-1T, SLS-12-017T, La nota: SLS-12-017T se puede establecer en el rango +12V to +15V SLS-24-012T ajustando R9 V.
  • Página 19 Linear Open Frame DC Power Supplies Silver Line Instruction Manual Models: SLS-05-060-1T, SLS-12-034T, Input AC Connections (See Case B) SLS-24-024T Primary Fuse Features (SLS-05-0601T) For use Connect Apply AC to: • Easy installation with strip terminal • Multi-Tap AC Inputs (SLS-12-034T) •...
  • Página 20 Serie SL - Lineales de Salida Sencilla & Múltiple Manual de la Instrucción Modelos: SLS-05-060-1T, SLS-12-034T, Entrada AC Conexiones (See Caja B) SLS-24-024T El fusible primario Características Para el (SLS-05-0601T) • Terminales de conexión fáciles de instalar. • Multi-Tap AC Las Entradas Conecte Aplique AC a: uso en:...
  • Página 21 Linear Open Frame DC Power Supplies Silver Line Instruction Manual Models: SLS-12-051T, SLS-15-045T, Input AC Connections (See Case C) SLS-24-036T, SLS-05-090-1T For use Connect Apply AC to: Primary Fuse Primary Fuse** Features 100 VAC 1-3, 2-4 1 & 5 1.6A / 125V 2A/125V •...
  • Página 22: Top View

    Serie SL - Lineales de Salida Sencilla & Múltiple Manual de la Instrucción Modelos: SLS-12-051T, SLS-15-045T, Entrada AC Conexiones (See Caja C) SLS-24-036T, SLS-05-090-1T Para el uso en: Conecte Aplique AC a: El fusible primario El fusible primario** Características • Terminales de conexión fáciles de instalar. •...
  • Página 23 Linear Open Frame DC Power Supplies Installation Step 1: Check the input AC connections Silver Line Instruction Manual Step 2: Connect the AC input according to table below. Models: SLS-05-030-1T, SLS-12-017T, Note: SLS-12-017T can be set to a +12V to +15V range by adjusting R9 V. ADJ. SLS-24-012T Features •...
  • Página 24 Serie SL - Lineales de Salida Sencilla & Instalación Dé un paso 1: Verifica las conexiones de entrada de C.A. Múltiple Manual de la Instrucción Dé un paso 2: Conecte a la entrada de C.A. según posponer abajo. Modelos: SLS-05-030-1T, SLS-12-017T, La nota: SLS-12-017T se puede establecer en el rango +12V to +15V SLS-24-012T ajustando R9 V.
  • Página 25 Linear Open Frame DC Power Supplies Silver Line Instruction Manual Models: SLS-05-060-1T, SLS-12-034T, Input AC Connections (See Case B) SLS-24-024T Primary Fuse Features (SLS-05-0601T) For use Connect Apply AC to: • Easy installation with strip terminal • Multi-Tap AC Inputs (SLS-12-034T) •...
  • Página 26 Serie SL - Lineales de Salida Sencilla & Múltiple Manual de la Instrucción Modelos: SLS-05-060-1T, SLS-12-034T, Entrada AC Conexiones (See Caja B) SLS-24-024T El fusible primario Características Para el (SLS-05-0601T) • Terminales de conexión fáciles de instalar. • Multi-Tap AC Las Entradas Conecte Aplique AC a: uso en:...
  • Página 27 Linear Open Frame DC Power Supplies Silver Line Instruction Manual Models: SLS-12-051T, SLS-15-045T, Input AC Connections (See Case C) SLS-24-036T, SLS-05-090-1T For use Connect Apply AC to: Primary Fuse Primary Fuse** Features 100 VAC 1-3, 2-4 1 & 5 1.6A / 125V 2A/125V •...
  • Página 28 Serie SL - Lineales de Salida Sencilla & Múltiple Manual de la Instrucción Modelos: SLS-12-051T, SLS-15-045T, Entrada AC Conexiones (See Caja C) SLS-24-036T, SLS-05-090-1T Para el uso en: Conecte Aplique AC a: El fusible primario El fusible primario** Características • Terminales de conexión fáciles de instalar. •...
  • Página 29 Linear Open Frame DC Power Supplies Silver Line Instruction Manual OVP (OPTIONAL) AC INPUT/DC OUTPUT Models: SLS-05-120-1T, SLS-12-068T, 1.250" (32) 9.00" (229) . 75" (1 Input AC Connections (See Case I2) SLS-15-060T, SLS-24-048T . 512" (13) 8.00" (203) . 551" Primary Fuse Apply AC Primary Fuse...
  • Página 30 Serie SL - Lineales de Salida Sencilla & Múltiple Manual de la Instrucción OVP (OPTIONAL) AC INPUT/DC OUTPUT Modelos: SLS-05-120-1T, SLS-12-068T, Entrada AC Conexiones (See Caja I2) 1.250" (32) . 75" (1 9.00" (229) SLS-15-060T, SLS-24-048T . 512" (13) 8.00" (203) .
  • Página 31 Linear Open Frame DC Power Supplies Silver Line Instruction Manual Models: SLS-12-051T, SLS-15-045T, Input AC Connections (See Case C) SLS-24-036T, SLS-05-090-1T For use Connect Apply AC to: Primary Fuse Primary Fuse** Features 100 VAC 1-3, 2-4 1 & 5 1.6A / 125V 2A/125V •...
  • Página 32 Serie SL - Lineales de Salida Sencilla & Múltiple Manual de la Instrucción Modelos: SLS-12-051T, SLS-15-045T, Entrada AC Conexiones (See Caja C) SLS-24-036T, SLS-05-090-1T Para el uso en: Conecte Aplique AC a: El fusible primario El fusible primario** Características • Terminales de conexión fáciles de instalar. •...
  • Página 33 Linear Open Frame DC Power Supplies Installation Step 1: Check the input AC connections Silver Line Instruction Manual Step 2: Connect the AC input according to table below. Models: SLS-05-030-1T, SLS-12-017T, Note: SLS-12-017T can be set to a +12V to +15V range by adjusting R9 V. ADJ. SLS-24-012T Features •...
  • Página 34 Serie SL - Lineales de Salida Sencilla & Instalación Dé un paso 1: Verifica las conexiones de entrada de C.A. Múltiple Manual de la Instrucción Dé un paso 2: Conecte a la entrada de C.A. según posponer abajo. Modelos: SLS-05-030-1T, SLS-12-017T, La nota: SLS-12-017T se puede establecer en el rango +12V to +15V SLS-24-012T ajustando R9 V.
  • Página 35 Linear Open Frame DC Power Supplies Silver Line Instruction Manual Models: SLS-05-060-1T, SLS-12-034T, Input AC Connections (See Case B) SLS-24-024T Primary Fuse Features (SLS-05-0601T) For use Connect Apply AC to: • Easy installation with strip terminal • Multi-Tap AC Inputs (SLS-12-034T) •...
  • Página 36 Serie SL - Lineales de Salida Sencilla & Múltiple Manual de la Instrucción Modelos: SLS-05-060-1T, SLS-12-034T, Entrada AC Conexiones (See Caja B) SLS-24-024T El fusible primario Características Para el (SLS-05-0601T) • Terminales de conexión fáciles de instalar. • Multi-Tap AC Las Entradas Conecte Aplique AC a: uso en:...
  • Página 37 Linear Open Frame DC Power Supplies Input AC Connections (See Case C) Silver Line Instruction Manual For use Connect Apply AC to: Primary Fuse Primary Fuse** Models: SLS-12-051T, SLS-15-045T, 100 VAC 1-3, 2-4 1 & 5 1.6A / 125V 2A/125V SLS-24-036T, SLS-05-090-1T 120 VAC* 1-3, 2-4 1 & 4 1.6A / 125V 2A/125V Features 220 VAC...
  • Página 38 Serie SL - Lineales de Salida Sencilla & Entrada AC Conexiones (See Caja C) Múltiple Manual de la Instrucción Para el uso en: Conecte Aplique AC a: El fusible primario El fusible primario** Modelos: SLS-12-051T, SLS-15-045T, 100 VAC 1-3, 2-4 1 & 5 1.6A / 125V 2A/125V SLS-24-036T, SLS-05-090-1T 120 VAC*...
  • Página 39 Linear Open Frame DC Power Supplies Silver Line Instruction Manual OVP (OPTIONAL) AC INPUT/DC OUTPUT Models: SLS-05-120-1T, SLS-12-068T, 1.250" (32) 9.00" (229) . 75" (1 Input AC Connections (See Case I2) SLS-15-060T, SLS-24-048T . 512" (13) 8.00" (203) . 551" Primary Fuse Apply AC Primary Fuse...
  • Página 40 Serie SL - Lineales de Salida Sencilla & Múltiple Manual de la Instrucción OVP (OPTIONAL) AC INPUT/DC OUTPUT Modelos: SLS-05-120-1T, SLS-12-068T, Entrada AC Conexiones (See Caja I2) 1.250" (32) . 75" (1 9.00" (229) SLS-15-060T, SLS-24-048T . 512" (13) 8.00" (203) .
  • Página 41 Linear Open Frame DC Power Supplies Silver Line Instruction Manual Model: SLS-24-072T Input AC Connections (See Case K) For use Connect Apply AC to: Primary Fuse Features 100 VAC 1-3, 2-4 1 & 5 4.0 A / 125 V • Easy installation with strip terminal •...
  • Página 42 Serie SL - Lineales de Salida Sencilla & Múltiple Manual de la Instrucción Modelos: SLS-24-072T Entrada AC Conexiones (See Caja K) Para el uso en: Conecte Aplique AC a: El fusible primario Características • Terminales de conexión fáciles de instalar. 100 VAC 1-3, 2-4 1 &...
  • Página 43 Linear Open Frame DC Power Supplies Silver Line Instruction Manual Model: SLS-24-120T Input AC Connections (See Case L) For use Connect Apply AC to: Primary Fuse Features 100 VAC 1-3, 2-4 1 & 5 6.0 A / 125 V • Easy installation with strip terminal •...
  • Página 44 Serie SL - Lineales de Salida Sencilla & Múltiple Manual de la Instrucción Modelo: SLS-24-120T Entrada AC Conexiones (See Caja L) Para el uso en: Conecte Aplique AC a: El fusible primario Características 100 VAC 1-3, 2-4 1 & 5 6.0 A / 125V •...
  • Página 45: Output Specifications

    Linear Open Frame DC Power Supplies Output Adjustment Silver Line Instruction Manual Step 1: Check the input AC connections Model: SLT12-20404-12T Step 2: Connect the AC input according to table below. Step 3: Use VR6 to adjust +V. Adj. to +15V or +12V. Step 4: Use VR4 to adjust -V.
  • Página 46: Voltaje/Las Calificaciones Actuales

    Serie SL - Lineales de Salida Sencilla & El Ajuste de Salida Múltiple Manual de la Instrucción Dé un paso 1: Verifica las conexiones de entrada de C.A. Modelo: SLT12-20404-12T Dé un paso 2: Conecte a la entrada de C.A. según posponer abajo. Dé...
  • Página 47 Linear Open Frame DC Power Supplies Output Adjustment Silver Line Instruction Manual Step 1: Check the input AC connections Model: SLT12-31010-12T Step 2: Connect the AC input according to table below. Step 3: SLT12-31010-12T can be set to +15V or +12V by adjusting VR6. Step 4: SLT12-31010-12T can be set to -15V or -12V by adjusting VR4.
  • Página 48 Serie SL - Lineales de Salida Sencilla & El Ajuste de Salida Múltiple Manual de la Instrucción Dé un paso 1: Verifica las conexiones de entrada de C.A. Modelo: SLT12-31010-12T Dé un paso 2: Conecte a la entrada de C.A. según posponer abajo. Dé...
  • Página 49 Linear Open Frame DC Power Supplies Output Adjustment Silver Line Instruction Manual Step 1: Check the input AC connections Step 2: Connect the AC input according to table below. Model: SLT12-61818-12T Step 3: Use VR6 to adjust to +V.Adj. +15V or +12V. Step 4: Use VR4 to adjust to -V.Adj.
  • Página 50: Serie Sl - Lineales De Salida Sencilla & Múltiple Múltiple Manual De La Instrucción

    Serie SL - Lineales de Salida Sencilla & El Ajuste de Salida Dé un paso 1: Verifica las conexiones de entrada de C.A. Múltiple Múltiple Manual de la Instrucción Dé un paso 2: Conecte a la entrada de C.A. según posponer abajo. Modelo: SLT12-61818-12T Dé...

Tabla de contenido