Features
• Easy installation with strip terminal
• Tight regulation: 0.05% Line; 0.05% Load
• Full Output Ratings to +50
o
C
• Built in OVP on 5 Volt Outputs
• OVP Option for 12V, 15V and 24V
• Foldback Current Limiting Overload Protection with
Automatic Recovery
General Specifications
Voltage/Current Ratings
Model Numbers
Output
SLS-12-051T
12 V / 5.1 A
SLS-15-045T
15 V / 4.5 A
SLS-24-036T
24 V / 3.6 A
SLS-05-090-1T
5 V / 9.0 A
Operating Temperature Range
0 to +50
o
C (Derate to 40% at +70
Temperature Coefficient (Typical)
+/- 0.01% /
Stability
Within +/- 0.05% (24 hours after warm-up)
Vibration
Per MIL-STD-810C, Method 514
Shock
Per MIL-STD-810C, Method 516
Linear power supplies have inherently low conducted and radiated noise levels.
For most system applications, these power supplies will meet the requirements
EMI/RFI
of FCC Class "B" and VDE 0871 for Class "B" equipment without additional
noise filtering.
Forced air. 20 CFM required for full rating Derate 30% for convection cooling.
Cooling
Input Specifications
100/120/220/230/240 VAC selectable +/- 10% except 230 VAC is +15%, -6%
Multi Input (all units)
Frequency Range
47-63 Hz (Typical is 60 Hz. Derate output 10% at 50 Hz)
50 µsec at 50% load changes for outputs rated up to 6A
Transient Response Time
100 µsec at 50% load changes for outputs rated 6A and over.
Units are not fused internally. For safe operation, user must provide input line
Fuse Requirements
fuse as per values given in table.
0.05% for +/- 10% change
Line Regulation
0.05% for 50% change
Load Regulation
3.0 mV maximum peak-to-peak
Ripple
DC Output Adjustment Range
+/- 5% minimum
All 5 volt outputs include built-in OVP as standard (setting is 6.2 V +/- 0.4 V).
Overvoltage Protection
OVP is optionally available on other outputs.
All units listed have remote sensing capability.
Remote Sensing
Overload Protection
125 to 150% foldback current limit
Linear Open Frame DC Power Supplies
Silver Line Instruction Manual
Models: SLS-12-051T, SLS-15-045T,
SLS-24-036T, SLS-05-090-1T
• Multi-Tap AC Inputs
• 100% Four-Hour Burn-in
• Please see enclosed "Terms & Conditions and
Sales & Policies & Procedures"
• UL Recognized
• CSA Certified
• CE Marked
• CB Certified
o
C)
o
C
Output Specifications
Input AC Connections (See Case C)
For use
at:
Connect
100 VAC
1-3, 2-4
120 VAC*
1-3, 2-4
220 VAC
2-3
230 VAC
2-3
240 VAC
2-3
*Note: Unit is shipped for 120V input from factory.
**Primary Fuse for SLS-24-036T
Mechanical Dimensions: Inches (mm)
Top View
. 38" (9.6 )
AC INPUT/DC OUTPUT
.50" ( 12.7)
. 50" ( 12.9)
75"
(19.1)
0.83 (21.08)
6.27 (159.26)
WEIGH T: 7.28 LBS.
(3.3 KG)
Note: The SLS models DC output can be adjusted with R13 V. ADJ.
R7 I. LIM is factory set and should not be adjusted by users.
Application Note: User needs to provide earth ground to power supply with either solder to Tab or using washer and nut assembly.
The SLS power supply is shipped from the factory with metal shorting straps connected between the + OUT and + S
terminals and the (-) OUT and (-) S terminals. This strapping configuration allows the output of the SLS to be taken
from either pair of terminals. This is the standard configuration.
The remote sense feature is enabled by removing the shorting straps and connecting the individual OUT and S
terminals to the appropriate points of the load. If an OVP circuit is used it should be connected to the + OUT and (-)
OUT terminals. The OVP should never be connected to the + S, - S terminals without the use of the shorting straps.
In all cases it is critical that the terminal screws be firmly tightened.
Contact Technical Services at 1-800-377-4384 or
[email protected] with any questions.
Visit our website at www.solaheviduty.com
Apply AC to:
Primary Fuse
1 & 5
1.6A / 125V
1 & 4
1.6A / 125V
1 & 5
0.8A / 250V
1 & 4
0.8A / 250V
1 & 4
0.8A / 250V
1.248" ( 31.7)
. 75" ( 19.1)
7.00 " ( 178)
. 551" ( 14)
6.250" ( 158.8)
MA X
R13
V. ADJ
R7
I.LIM
188"
°
MTG HOLES (1 2 P LACES)
OV P ( OPTIONAL )
(4.8 )
5
1
3
2
4
Cas e C
PEM NU T HOLES
8-32 MTG (4 PLACES)
Case C
Primary Fuse**
2A/125V
2A/125V
1A/250V
1A/250V
1A/250V