INSTALLING THE PAYMENT SYSTEM
The machine is sold without payment system, therefore
the installer of such a system has sole responsibility for
any damage to the machine or to things and persons
caused by incorrect installation.
- Fit the coin mechanism and make sure that the selec-
tor coin inlet and the coin return lever are aligned with
the coin chute and the selector opening cam;
- according to the type of coin mechanism, to achieve
such alignment move the plastic inserts in the adjacent
openings;
- ensure that all relevant parameters are programmed
correctly.
Fig. 15
1 - Selector opening cam
2 - Coin chute
3 - Openings for plastic inserts
CONNECTING THE MACHINE
TO THE POWER SUPPLY
The machine is designed to operate under single-phase 230
V~ voltage and is protected by 10 A fuses.
Before making the connection ensure that the rating corre-
sponds to that of the power grid, and more specifically:
- the supply voltage rating should be within the range
recommended for the connection points;
- the main switch should be suitable to withstand the
peak load required, and at the same time should
ensure proper omnipolar disconnection from the
power grid with an opening gap of the contacts of at
least 3 mm.
The main switch, the power outlet and the plug should
be located within easy reach.
The electrical safety of the machine is ensured only when
it is correctly earthed according to the safety standards in
force.
© by NECTA VENDING SOLUTIONS SpA
This fundamental safety requirement must be duly verified,
and if in doubt the system must be carefully tested by quali-
fied technicians.
The power cable must be fitted with a fixed plug.
Any replacement of the power cable should be made by
qualified and suitably trained personnel only using cables
type HO5 RN-F, HO5 V V-F or H07 RN-F with a 3x1.5 mm
section.
Do not use adapters, multiple sockets and/or exten-
sions.
THE MANUFACTURER DECLINES ALL RESPONSIBIL-
ITY FOR ANY DAMAGE CAUSED BY NONCOMPLI-
ANCE WITH THE ABOVE MENTIONED PRECAUTIONS.
CONFIGURATION OF THE
DISPENSING MODULES
Should it be necessary to change the size of the products
to be dispensed, the dispensing modules for cans or the
columns (single and double) can be reconfigured by using
some elements available as optional.
The machine is supplied with a table containing details
of the settings as determined by the manufacturer
during tests and experiments performed with the most
common product types.
Settings for other product types can be determined by
following the information indicated below.
In any case it will be necessary to test each module to
be sure of its correct operation.
Products which are too irregular or not firm enough may not
be suitable for automatic dispensing.
DISPENSING MODULES FOR CANS
The modules can be adapted for dispensing 250, 330 and
355 cc cans by simply replacing the guides fitted at the inlet
of the two upper chutes with others which are adequately
sized.
The guide has the function of preventing the cans from
rotating and getting into a transverse position.
The guides are secured to the left hand wall of the module
(see Fig. 6) and are fixed with only one screw.
COLUMNS
The columns can be adapted for dispensing:
- 62 to 73 mm dia. bottles with 246 to 285 mm height in
a single row;
- 62 to 73 mm dia. bottles with 196 to 246 mm height in
a double row;
- 66 mm dia., 250 cc - 330 cc - 355 cc cans in quadruple
row.
The following procedure must be adopted.
According to the type of bottle it will be necessary to
make some adjustments to the settings indicated be-
low.
50
2
01 10 126-03