• Always switch off and disconnect the power supply before cleaning.
• Warm, soapy water is recommended for cleaning. Cleaning agents may leave harmful residues.
• DO NOT wash the base unit, instead wipe the exterior with a damp cloth.
• Check regularly the connectors of the water inlet and outlet tubes and drain the little surplus water that may
leak.
• If the ice make will be nnused for a long period, please switch off the power switch and wipe the inner liner
of the ice storage container with a clean rag.
• When plugging or unplugging, the plug should be held by hand and the wires should not be dragged heavily.
Problem
Device does not work
without any lights
coming on.
Device does not
work, only switch
light comes on.
Device does not
work, ICE FULL light
comes on.
Device does not
work, ICE FULL and
FAULT flash together.
Device does not
work, FAULT light
flashes.
WATER LOW and ICE
FULL flash together
or the FAULT flash
rapidly.
FAULT, WATER LOW,
ICE FULL three lights
flash slowly.
Cleaning and Care
Troubleshooting
Possible Cause
Power suply is interrup-
ted.
Power supply voltage is
not correct.
Power supply voltage is
not correct.
PCB board damaged.
Ice full occur.
Ambient temperature is
below 6°C.
ICE FULL sensor is dema-
ged or not connected.
Condenser sensor dema-
ged or does not run.
Refrigerant leakage.
Compressor does not run. Compressor demaged or ambient temperature is above
Ambient temoperature is
below 6°C.
The hall sensor is not
in correct position or
damaged.
Paddle motor damaged.
Solution
Check the power supply.
Cut off the power supply.
Cut off the power supply.
Contact a service agency for repair or replacement.
Remove th ice cubes from basket.
Keep the ambient temperature above 7°C, then restart
the unit.
Contact a service agency for repair or replacement.
Contact a service agency for repair or replacement.
Contact a service agency for check or replacement.
43°C.
Keep the ambient temperature above 7°C, then restart
the unit.
Contact a service agency for adjustment or replace-
ment.
Contact a service agency for replacement.
10