Oreck Revitalize FK50100 Serie Manual Del Usuario página 31

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Problem
Cause
Cleaner will
Clean Water Solution Tank is empty.
not dispense
Clean Water Solution Tank not installed properly.
Needs service.
Hose nozzle will not
Air is trapped in the pump and hose.
spray after filling the
The connection to the tool port is loose.
Clean Water Tank or
Detergent Container
Motor noise becomes
Dirty Water Tank is full.
high-pitched
Dirty Water Tank is clogged.
Air path is clogged.
The float in the Dirty Water Tank has been activated.
Brushrolls are
Belt needs to be changed.
not spinning
Something is jammed in the brushroll.
Needs service.
Resolution
Fill Clean Water Solution Tank.
Review Clean Water Solution Tank Installation.
Take to service center. To find nearest location, visit our website at
www.oreck.com or call 1.800.989.3535.
Turn on the cleaner. If hose does not spray, prime the pump by lowering
the hose down to the floor and hold the trigger for up to 1 minute.
Ensure that the Hose is securely connected to the hose connection.
Empty Dirty Water Tank.
Clean Dirty Water Tank.
Unclog air path.
Review Emptying
Cleaning the Dirty Water Tank.
&
Refer to how to change belt.
Remove jammed item from cleaner with unit turned off and unplugged.
31
Tabla de contenido
loading

Este manual también es adecuado para:

961151929

Tabla de contenido