Troubleshooting; Fcc Statement - HoMedics TOTALCOMFORT UHE-CM65 Manual Del Usuario

Ocultar thumbs Ver también para TOTALCOMFORT UHE-CM65:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

TROUBLESHOOTING

PROBLEM
POSSIBLE CAUSE
No Power/No Mist from Spout
• Unit is not plugged in
• No power at unit
• Low water level
Peculiar Odor
• Unit is new
• If unit is in use, the odor
may be a dirty tank or old
tank water
Excessive Noise
• Unit is not level
• Low water level
White Dust Accumulation
• Hard water used
• Demineralization Cartridge
needs replacement
SOLUTION
• Plug unit in
• Turn the Power/Mist knob
clockwise to turn the
power on
• Check circuits and fuses or
try a different outlet
• Refill the tank with water
• Open the water tank cap and
keep it in a shady, cool place
for 12 hours
• Empty the old water,
clean the tank and fill
with clean water
• Place unit on a flat,
even surface
• Check the water level. Refill
the tank if the water is low
• Use distilled water and a
Demineralization Cartridge
• Replace Demineralization
Cartridge
10

FCC STATEMENT

NOTE: This product has been tested and complies with the requirements for Federal Communication
Commission, Part 18. Although this product is tested and complies with FCC, it may interfere with other
devices. If this product is found to interfere with another device, separate the other device and this
product. Conduct only the user maintenance found in this instruction manual. Other maintenance and
servicing may cause harmful interference and can void the required FCC compliance.
Industry Canada ICES-001 Compliance Label: CAN ICES-1/NMB-1
Caution: All servicing of this humidifier must be performed by authorized HoMedics service
personnel only.
11
Tabla de contenido
loading

Tabla de contenido