Water leakage from shaft
of the pump (rotating joint
between the pump and the motor)
The motor does not start
The motor stops
*
: This type of repair requires the intervention of qualified personnel.
Contact your Jacuzzi® dealer or an authorised Service Centre.
It is the responsibility of the installer/owner to ascertain compliance with specific local regulations prior to installation. Jacuz-
zi Europe S.p.A. gives no guarantee in this respect and declines all responsibility regarding the compliance of the installation
performed.
Motor bearings worn or faulty
The impeller rubs against the pump body
Solid bodies in the pump
Pump mechanical seal worn or defective
No power
Main switch has tripped
Voltage too low
Circuit breaker has tripped
Incorrect or faulty connections
Shaft and impeller blocked
Motor windings burnt
Faulty contact on motor
start-up
The function has ended
Overload
Power supply cables not suitable
30
*
*
*
*
Turn on the mains switch
Turn on switch
Contact an electrician or the organization
that provides electricity
Reset breaker
*
*
*
*
Press the key
again
Let the motor cool,
the problem should disappear.
If it persists, see *
Consult an electrician