The DEL Ozone Eclipse works under vacuum. The Injector Manifold draws the ozone/air gas mixture out of the ozone
generator and mixes it into the water leaving behind some un-dissolved gas bubbles. These bubbles can affect certain
pool system components, so care must be taken when installing the ozone Injector Manifold.
The diagrams below cover common plumbing configurations. For other configurations or installation questions, please
call DEL Ozone Residential Pool & Spa Technical Support at 1 (800) 676-1335, ext. 293, or e-mail:
Pool Cleaners (i.e. Polaris 360): Always plumb the cleaner t-fitting before the Eclipse injector to prevent gas from
affecting the operation of the cleaner.
Salt Chlorinator: A Salt Chlorinator may be plumbed on either side of the Eclipse injector.
Chlorine Tab / Mineral Erosion Feeder: Always plumb the Eclipse injector after any erosion feeder to avoid gas
accumulating in the feeder.
In-Floor Cleaning System: The Eclipse Injector must be on a different pool return leg than any In-Floor Cleaning
system to avoid excess back pressure on the Injector. This will also prevent gas intrusion and high oxidizer levels in
zone valve and cleaner heads.
Water Features: Avoid plumbing the Injector Manifold into any leg with excessive back pressure such as those
going to fountains, restrictive wall fittings, etc.
DEL Total Eclipse: Also correct location for Total Eclipse By-Pass. Back pressure on Total Eclipse must be minimal.
Sanitizer
Heater
Actuator
Heater
To Spa
DEL Ozone, Inc.
www.delozone.com
APPENDIX A
Eclipse Installation – Plumbing
Diagram 1: Pool Only
Pool
Cleaner
Sanitizer
Diagram 2: Pool/Spa Combo
In-Floor
Cleaner
Water
Features
Sanitizer
Eclipse Installation & Operations Manual
Eclipse
Injector
Sanitizer
Manifold
Eclipse
Eclipse
Sanitizer
Injector
Manifold
Eclipse
13
Pool
Pool
4-1393-01_Rev.A