Eclipse Installation & Operations Manual
d. Check that the check valve is installed with the arrow pointing
towards the injector.
e. Be sure that the check valve has not become fouled with
debris. Disconnect the Ozone Tube from the injector. With the
pump running, cover the end of the injector with your thumb,
and feel for suction. If there is sufficient suction without the
check valve, replace the check valve with a new one.
4D-3 Symptom: Ozone Tube becomes yellow/brown and brittle.
1. The high concentration of ozone created by the Eclipse family of
ozone generators, as well as environmental conditions like UV
sunlight will tend to deteriorate the supplied Ozone Tube. This
is normal and acceptable, as long as the tubing doesn't become
cracked and leak. Because of this, the Ozone Tube and Check
Valve should be replaced every year.
4D-4 Symptom: Can't get ball to stay in the center of flowmeter.
1. The flowmeter provided is a general tool to setup flow to the
ozone generator. Flow will vary depending on pressures across
the injector, and therefore can be affected by things such as filter
or strainer loading. The ozone generator's efficiency is optimized
near the center of the flow meter. The Eclipse ozone generator
will still perform well at flows above and below the recommended
range. However, the ball must be moving and not stuck on the
bottom of the flowmeter.