BATTERY CHARGING TIMES
CCA = Cold Cranking Amps RC = Reserve Capacity Ah = Amp Hour
BATTERY SIZE/RATING
SMALL BATTERIES
Motorcycle, garden tractor, etc.
CARS AND
TRUCKS
MARINE/DEEP-CYCLE
Times are based on a 50% discharged battery and may change, depending on
age and condition of battery.
CHARGE COMPLETION AND MAINTAIN
MODE (FLOAT MODE MONITORING)
Charge completion is indicated by
the pulsing green LED and the digital
display showing FULLY CHARGED
AUTO MAINTAINING. This means that
the charger has stopped charging and
has switched to the Maintain Mode of
operation. NOTE: If the charger has to
provide its maximum maintain current for
a continuous 12 hour period, it will go into
Abort Mode (see Aborted Charge section).
This is usually caused by a drain on the
battery, or the battery could be bad. Make
sure there are no loads on the battery. If
there are, remove them. If there are none,
have the battery checked or replaced.
MAINTAINING A BATTERY
The 28.71345 maintains 6 and 12 volt
batteries, keeping them at full charge.
It is not recommended for industrial
applications.
NOTE: The maintain mode technology
allows you to safely charge and maintain
a healthy battery for extended periods
of time. However, problems with the
battery, electrical problems in the
vehicle, improper connections or other
unanticipated conditions could cause
excessive current draws. As such,
occasionally monitoring your battery and
the charging process is required.
DESULFATION MODE
If the battery is left discharged for an
extended period of time, it could become
sulfated and not accept a normal charge.
If the charger detects a sulfated battery,
the charger will switch to a special mode
of operation designed for such batteries.
If successful, normal charging will resume
after the battery is desulfated. Desulfation
could take up to 8 hours. If desulfation
fails, charging will abort, the yellow/orange
LED will flash, and the display will show
CHARGING ABORTED BAD BATTERY.
200-315 CCA
315-550 CCA
550-1000 CCA
CHARGE RATE/TIME
6-12 Ah
12-32 Ah
40-60 RC
60-85 RC
85-190 RC
80 RC
140 RC
160 RC
180 RC
ABORTED CHARGE
If charging cannot be completed normally,
charging will abort. When charging aborts,
the charger's output is shut off, the yellow/
orange LED will flash, and the display
will show CHARGING ABORTED BAD
BATTERY. To reset after an aborted
charge, unplug the charger from the outlet,
wait a few moments and plug it back in.
USING THE ENGINE START SETTING
Your battery charger can be used to jump
start your car if the battery is low. Follow
all safety instructions and precautions for
charging your battery. Wear complete eye
protection and protective clothing.
WARNING: Using the ENGINE START
setting WITHOUT a battery installed in
the vehicle could cause damage to the
vehicle's electrical system.
NOTE: If you have charged the battery
and it still will not start your car, do not
use the Engine Start setting, or it could
damage the vehicle's electrical system.
Have the battery checked.
1. Set the ON/OFF switch to the OFF
position.
2. With the charger unplugged from the
AC outlet, connect the charger to the
battery, following the instructions given
in sections 6 and 7.
3. With the charger plugged in and
connected to the battery and chassis,
set the ON/OFF switch to the Engine
Start position, and then press the
RATE SELECTION button until the
ENGINE START LED is lit.
4. When the display shows ENGINE
START READY, crank the engine
until it starts or 3 seconds pass. If the
engine does not start, wait 3 minutes
(until the display shows ENGINE
START READY) before cranking
again. This allows the charger and
battery to cool down.