METHOD OF USE

To dry correctly is recommended rising well to remove all traces of
soap.
These models operate by hand detection. Place hands 4-6" (10 - 15
cm) from the air outlet and the dryer will start working. Once activated,
immediately place hands in air flow and rub together until dry.
This machine will stop 2-3 seconds after use.
Sensor
If the sensor is blocked due to vandalism, the dryer will completely stop
working.
NOTE: let a minimum separation of 15" (40 cm.) between appliance
and any shelf, marble, worktop or washbasin.
Sensor
Figure 6
PREVENTATIVE MAINTENANCE AND CLEANING

1. Preventative maintenance

Correct cleaning of the unit will lengthen its working life considerably. When in use, the
machine will accumulate dust inside which should be cleaned out every six months.

2. Cleaning method

1. Turn off power to the unit.
2. Remove cover using security wrench (See Dismantling for Installation).
3. Clean away any accumulated dust on the fan with a soft bristle brush while rotating it
manually. Use the same brush, to clean away all accumulated dust from the other
components. Carefully remove any dust from the electronic circuit board and hand
detecting sensors using a fine brush.
4. Use brush to clean the air inlet grill and make sure the LED visor is completely clean.
6. Reconnect power to the unit and let it run continuosly, removing any excess dust.
7. Turn off power to the unit and install cover per the Mounting Instructions.
Caution: Do not damage or force any components.
Cleaning the cover - Use only a wet cloth to clean the covers. Do not use any kind
of detergent, acids, lye, abrasives, hydrocloric acid, etc.
-4-