Detection Of Failures And Their Fixing; Error Codes - Bartscher 296318 Manual De Instalación, Uso Y Mantenimiento

Ocultar thumbs Ver también para 296318:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 67
ENGLISH
7.1.

Detection of failures and their fixing

Failure
Insufficient heating of the
cooking zone
Continuous heating of cooking
zone at maximum power
Cooking zone operates
without a pot
Small metal objects are
heated up
Cooking zone does not
GB
heat up
The device does not respond
The fuses glow when the
appliance is switched on
7.2.

Error codes

Malfunction errors are detected by the
generator and reported to the operator
This is a sequence of green indicator light flashes for error: E1 ↔ 06:
long
Red indicator light is lit for a long time in case of error
Possible reason
Unsuitable cookware
Defective temperature control
knob
Defective pot detection
Defective pot detection
Pot diameter smaller than
12 cm or defective pot
detection
Damaged generator
Fuses blown or power cable
damaged
Generator short-circuit
When error occurs, a green indicator light
makes one long flash followed by short
flashes. Short flashes are repeated at equal
intervals. A total number of short flashes
corresponds to the error number.
long
10
Solution
Use suitable cookware
Check/replace the knob
Replace the generator or have
it repaired
Replace the generator or have
it repaired
Use suitable pots
Replace the generator or have
it repaired
Check the network connection
Replace the generator or have
it repaired
Tabla de contenido
loading

Este manual también es adecuado para:

296319Id092m01Id091m01