Jacuzzi flexa tower ELT4 Manual De Instalación página 15

Ocultar thumbs Ver también para flexa tower ELT4:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

Connection to the electrical system of the building must be made
using a sheathed cable with specifications of not less than H 05 VV-
F 3x2.5 mm
2
.
The electric system of the building must be e-
quipped with a 0.03-A differential switch.
The FLEXA shower enclosures are equipped with a terminal, fitted
on the framework and marked with the symbol
tential connection of the surrounding metal masses, as estab-
lished by EN 60335-2-105 standards.
CAUTION! Disconnect the appliance from the elec-
tricity prior to performing any maintenance opera-
tions.
JACUZZI declines any and all responsibility if:
If the installation is performed by personnel not qualified and/or
not certified to perform the said installation
The current legal requirements and standards regarding the
electric systems of buildings in the country in which the installa-
tion is performed are not respected.
The requirements for installation and maintenance contained in
this manual are not respected.
Unsuitable and/or uncertified materials are used for installation.
FLEXA TOWER and FLEXA TOWER COMPACT shower enclo-
sures are not installed in compliance with the aforesaid stan-
dards and regulations.
Improper operations are performed which reduce the degree of
protection against the jets or modify the protection against elec-
trocution due to direct or indirect contact, or generate anom-
alous conditions of isolation, current dispersion or overheating.
Components or parts of the apparatus are changed or modified
with respect to the state in which they were supplied, thereby
relieving the manufacturer of all responsibility.
The apparatus is repaired by unauthorised personnel or repaired us-
ing replacement parts that are not original Jacuzzi parts.
, for the equipo-
15

Hide quick links:

Tabla de contenido
loading

Tabla de contenido