Plantillas de Vitrocerámica
WIRING DIAGRAM
Warning! Remember to connect the safety circuit to the connection box
terminal marked with
must have a safety switch which enables the power to be cut off in case of
emergency. The distance between the working contacts of the safety switch
must be at least 3mm.
Before connecting the ceramic hob to the power supply it is important to read
the information on the data plate and the connection diagram.
CONNECTION DIAGRAM
Caution! Voltage of heating elements 230V
Caution! ln the event of any connection
the safety wire must be connected to the
For 230 V earthed one-
1
phase connection, bridges
connect 1-2 terminals, safety
wire
to
.
2 For 400/230V earthed two-
phase connection, the safety
wire to
.
L1=R,L2=S,L3=T,N=earth terminal, PE= safety wire terminal
• The cable connections must be in accordance with the diagram located
on the bottom of the hob.
• You should use a good quality screwdriver to carefully, fully tighten ALL
of the terminal screws.
• If when the hob is first switched on, only two of the zones work, you
should recheck that the terminal screws are all fully tightened. This
should be done before contacting the Customer Care Department.
• IMPORTANT: The appliance must NOT be connected to the mains
supply by means of a 13A plug and socket.
. The electricity supply for the ceramic hob
PE terminal
www.derkochline.com
1
2
3
Recommended
type of connection
4
lead
1
2
3
L1
4
H05VV-F 3G2.5
PE
N
1
2
3
L1
L2
H05VV-F 4G2.5
4
PE
N
Ceramic Hob
44