Fitting guidelines
2
1
Remember that the connection wire should match the connection type and the
power rating of the ceramic hob.
The connection cable must be secured in a strain-relief clamp.
E-VIII.2 Assembly of ceramic hob Olpe:
• Make an opening with the dimensions given in the diagram for the hob to be
mounted on the worktop.
• Check seal for perfect fit and overall cover. Lower the electric hob into place and
align correctly.
• Using a standard screwdriver, tighten the tension clamps evenly starting at the
centre and moving diagonal, until the built-in rim is tight on the worktop.
Cut a hole in the worktop that corresponds with the drawing shown above.
IMPORTANT: You must observe the ventilation requirements shown in the
drawing opposite.
The ceramic hob is manufactured to work with one-phase
alternating current.The voltage rating of the ceramic hob
heating elements is 220-240V. Adapting the ceramic hob
to operate with two-phase current is possible by
appropriate bridging in the connection box according to
the connection diagram below. The connection diagram
is also found on the cover of the connection box.