Pentair SIATA SFE-EV PRO Manual De Instrucciones página 22

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 102
End
Table 5: Advanced Menu
Inhibit regeneration End Time.
End time of the regeneration inhibit.
The option is displayed only for Duplex system type and only if IM=On
Water Meter Number.
The option is displayed only for Duplex system type and with Modular
not Active (M=0)
Relay activation mode. Press the
. Following the activation modes available:
Activation
Availability
mode
1C (A)
2C (A)
3C (A)
4C (A)
Only for duplex
P1
1C (B)
2C (B)
3C (B)
4C (B)
1C
Only for simplex
2C
P2 and custom
3C
P3
4C
5C
6C
Only for custom
7C
P3
8C
9C
ri
For all
EC
SA
For duplex system P1 and Modular active only relay 3 is available.
For duplex system P1 and Modular not active, stages from 1C to 4C will be available for both column A and B
Remote regeneration start mode: In case a remote regeneration is
initiated, this can be an immediate regeneration if Sr is set to "I", or a
delayed regeneration (starting at the programmed time) if Sr is set to "d".
To change the value, use the
confirm.
Remote start delay in minutes: duration in minute of the external signal
on port 15/16 of terminal strip to start a regeneration.
Interval in weeks before maintenance is required. Press
buttons to change. The interval is expressed in weeks.
Technical service telephone number. The telephone number may be set
to a maximum of 7 fields, each consisting of 4 digits. The number lit on
the upper part of the display identifies the current field. Press the
button to change the number or
button for 3 seconds to program the next 4 digits. Press and
the
button to confirm the phone number.
release the
End of programming
Page 22
or
button to select the relay to program then confirm with
Characterization
Description
Default
1th regen. stage column A
OFF
2th regen. stage column A
OFF
3th regen. stage column A
OFF
4th regen. stage column A
OFF
1th regen. stage column B
OFF
2th regen. stage column B
OFF
3th regen. stage column B
OFF
4th regen. stage column B
OFF
1th regen. stage
OFF
2th regen. stage
OFF
3th regen. stage
OFF
4th regen. stage
OFF
5th regeneration stage
OFF
6th regeneration stage
OFF
7th regeneration stage
OFF
8th regeneration stage
OFF
9th regeneration stage
OFF
Regeneration in progress
OFF
End of regeneration
OFF
Salt Alarm
OFF
, push the
button to
and
to go to the next number, press
00:00
20:00
23:59
1
1-2
Min-Max
OFF-Duration phase1
OFF-Duration phase2
OFF-Duration phase3
OFF-Duration phase4
OFF-Duration phase1
OFF-Duration phase2
OFF-Duration phase3
OFF-Duration phase4
OFF-Duration phase1
OFF-Duration phase2
OFF-Duration phase3
OFF-Duration phase4
OFF-Duration phase5
OFF-Duration phase6
OFF-Duration phase7
OFF-Duration phase8
OFF-Duration phase9
OFF-On
OFF-99
OFF-On
i
i or d
1
0-99
Of
of-52
N.A.
N.A.

Capítulos

Tabla de contenido

Solución de problemas

loading

Tabla de contenido