CONNECTIONS
Precautions
• The following connections should be made by qualified service personnel or system installers in accordance
with all local codes.
• See the reverse side of the cover page for main lead connection.
Note:
When powered up, the unit performs a self-check (including one panning, tilting, zooming and focusing opera-
tion).
• 24 V AC Power Supply Connection
Recommended wire gauge sizes for 24 V AC line
#24
Copper wire size
(AWG)
(0.22mm
Length
(m)
of cable
(ft)
(approx.)
Accessory Connector Information
Pin no.
Power source
1
24 V AC LIVE
2
24 V AC NEUTRAL
3
Ground
4
Not use
How to Assemble the Cable with the Accessory
Connector
Strip back the cable jacket approx. 3 mm (0.1 inch) and
separate the individual conductors.
Approx.
Approx.
3 mm (0.1 inch)
3 mm (0.1 inch)
Up A
Up
Contact
Contact
220 V - 240 V AC (WV-CS570)
24 V AC (WV-CS574E)
Data port
Video output
Alarm out
✻ The coaxial cable length (RG-59/U, BELDEN 9259) for the connection
is up to 1 200 meters (4 000 ft.)
#22
#20
2
)
(0.33mm
2
)
(0.52mm
2
)
20
30
45
65
100
160
4
2
Wire
Wire
Insert
Insert the wire until A position
Insert the wire until A position
and clamp the contacts.
and clamp the contacts.
BNC plug
Alarm in
Prepare the individual conductors for clamping. Use
MOLEX band tool part number 57027-5000 (for UL-
Style Cable UL1015) or 57026-5000 (for UL-Style
UL1007) for clamping the contacts.
#18
After clamping the contacts, push them into the proper
(0.83mm
2
)
holes in the accessory connector of this camera until
75
they snap in place.
260
3
1
CAUTIONS
• Shrinking the cable-entry seal is a one-time proce-
dure. Do not shrink the cable-entry seal until ascer-
taining that the unit is functioning.
• CONNECT THIS TO 24 V AC CLASS 2 POWER SUP-
PLY ONLY.
-17-
24 V AC cable
RS485 cable
Coaxial cable
To VIDEO IN
(CAMERA IN)
BNC plug
To sensors
To indicators
Up
Up
Contact
Contact
Wire
Wire