INSTALLATION OF THE STOP LIMIT
SWITCHES
1. Place the gate in the maximum closed position, and then
attach the limit switch screw as shown in the figure.

ELECTRICAL CONNECTIONS

VULCAN-230V / VULCAN-120V
YELLOW - GREEN
GND
BLUE
COMMON
BLACK
OPENING / CLOSING
BROWN
CLOSING / OPENING
WARNING: Always connect the earth cable to the
mains power earth system. Use the special fastom shown
in the figure, and a cable with a minimum cross sectional
area of 2.5 mm
2
VULCAN-24V
BLUE
OPENING / CLOSING
BROWN
CLOSING / OPENING
Hereafter the directions to follow to connect the cables of the
encoder to the control unit:
Red cable
-
power supply of accessories [+ 24VDC]
Black cable
-
common inputs [COM (-)]
Blue cable
-
signal of the encoder
White cable
-
signal of the encoder
Shielding braid sheath
Check that the ground of the power supply of the accessories is
connected to the common accessories
WARNING: extensions of the cables must be made
only with a 4x0,22 shielded cable with polyethylene
sheath
-
common input [COM (-)]
2. Place the gate in the maximum open position, and then
attach the limit switch nut as shown in the figure, and
tighten the screw.