General Information; Intended Use; Technical Data - OWIM H13726 Instrucciones De Utilización Y De Seguridad

Ocultar thumbs Ver también para H13726:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

Premium weather station

1. General information

ATTENTION! READ OPERATING INSTRUCTIONS
BEFORE USE! KEEP OPERATING INSTRUCTIONS
IN A SAFE PLACE! THIS PRODUCT IS NOT A
TOY! KEEP OUT OF REACH OF CHILDREN.
Read the operating instructions carefully and use
the product as described in the instructions to avoid
injury and damage. We accept no responsibility for
damage resulting from inappropriate use and fail-
ure to comply with the safety instructions.
Symbols used in these instructions:
WARNS OF RISk OF INjURy!
The word DANGER warns of possible risks of
severe or fatal injury.
The word CAUTION warns of possible risks of
minor injury or damage.
POINTS TO FURTHER
INFORMATION!

2. Intended use

The weather station informs you of the current
weather conditions and provides a weather forecast.
The weather station is equipped with a rain gauge,
wind gauge, barometer, radio clock and calendar.
Only for personal use. Not for commercial use.

3. Technical data

Measuring Range:
Room Temperature:
Outside Temperature:
General information / Intended use / Technical data
0.0 °C to +50.0 °C,
Resolution: 0.1 °C
32.0 °F to 122.0 °F,
Resolution: 0.1 °F
–20.0 °C to +60.0 °C
Resolution: 0.1 °C
Air humidity:
Air pressure:
Wind speed:
Rainfall measurement:
Outdoor sensor range:
Exceeded range of measurement:
The following displays can be expected outside of
the range of measurement:
Readings below the measurement values:
– Room temperature below 0 °C: LL.L
– Outdoor temperature below –50 °C: LL.L
– Air humidity below 20 %: 20 %
– Air pressure below 850 hPa: 850 hPa
– Heat Index below 14 °C: LL.L
– Dew Point below 0 °C: LL.L
– Wind Chill below –90 °C: LL.L
Values above the measurement values:
– Room temperature above 50 °C: HH.H
– Outdoor temperature above 70 °C: HH.H
– Air humidity above 99 %: 99 %
– Air pressure above 1050 hPa: 1050 hPa
– Heat Index above 60 °C: HH.H
– Dew Point above 60 °C: HH.H
– Wind Chill above 60 °C: HH.H
– Rainfall quantity above 9999 mm: HHH
– Wind speed above 50 m / s: 50 m / s
WARNING!
The display becomes increasingly less clear in tem-
peratures under approximately –20 °C. Depending
on the type of battery, power limitations are to be
–4.0 °F to +140.0 °F
Resolution: 0.1 °F
20 to 99 %
Resolution 1 %
850 mb to 1050 mb
850 hPa to 1050 hPa
25.1 inHg to 31 inHg
(mercury column in inches)
0–30 m / s
0–108 km / h
0–67 mph
0–58.3 knot
0–11 Beaufort
0–9999 mm
0–393.66 inch
25 m (open area)
GB/MT
65

Hide quick links:

Tabla de contenido
loading

Tabla de contenido