Routing A Circular Arc Profile / Fig. H; Maintenance And Cleaning; Maintenance; Cleaning - Parkside POF 1300 Instrucciones De Utilización Y De Seguridad

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Operation / Maintenance and cleaning / Disposal
j
Place the guide fence
the workpiece. Now carry out the fine adjust-
ment. Turning the screw for the fine adjustment
of the guide fence clockwise reduces the
28
distance. Turning the screw for the fine adjustment
of the guide fence anticlockwise increases the
28
distance. The stirrup
of the guide fence indicates the corrections on
the scale.
j
After the device has been lowered, apply the
clamping lever
15
j
Carry out the routing process using uniform
speed and pressure (see Figs. F, G).
j
After the routing process lift the device from the
workpiece and switch it off.
routing a circular arc
Q
profile / Fig. H
j
Reverse the guide fence
upwards) and push it into the guide rails
the base plate
. Fasten it in place with the
5
locking screws
.
21
j
Now screw the centring pin
nut
for centring pin through the outer hole
34
of the guide fence
the side of the spanner
pressure.
j
Insert the centring pin
of the circle. Now carry out the fine adjustment.
Turning the screw for the fine adjustment of the
guide fence
clockwise reduces the radius.
28
Turning the screw for the fine adjustment of the
guide fence
anticlockwise increases the
28
radius. Notice that the stirrup
adjustment of the guide fence moves with refer-
ence to the scale of the guide fence
this process.
j
Now guide the device with even speed and
pressure over the workpiece surface. Notice
that the path of guide fence
the setting on the stirrup
ment of the guide fence.
j
note: You can make changes to the radius of
the circle to be machined by changing the
position of the guide fence
44 GB/MT
against the edge of
27
for the fine adjustment
29
by turning it anticlockwise.
(stop edge faces
27
22
with the wing
33
. Use the small recess at
27
to provide counter
37
into the marked centre
33
for the fine
29
during
27
is controlled by
27
for the fine adjust-
29
.
27

Maintenance and cleaning

Q

Maintenance

Q
j
The device requires no maintenance.
j
Have repairs carried out only by an electrical
power tool specialist or your service centre.

Cleaning

Q
m Warning! Pull the mains lead out of the mains
socket before you clean the device, otherwise there
may be risk of injury .
j
Always keep the device and the ventilation
slots clean, dry and free of oil or grease. Dirty
devices increase the risk of injury (e.g. by slip-
ping). You will work better and more safely with
clean cutting tools.
j
of
Do not allow any liquids to enter the inside of
the device, otherwise there may be a risk of
electric shock. Use a dry cloth to clean the
housing.
Never use petrol, solvents or cleaning agents
that might attack plastic.

Disposal

Q
The packaging is wholly composed of
environmentally-friendly materials that can
be disposed of at a local recycling centre.
Do not dispose of electrical
power tools with the household
rubbish!
In accordance with European Directive
2002 / 96 / EC (covering waste electrical and elec-
tronic equipment) and its transposition into national
legislation, worn out electrical power tools must be
collected separately and taken for environmentally
compatible recycling.
Contact your local refuse disposal authority for
more details of how to dispose of your worn out
electrical devices.