RADIO SPECIFICATIONS
- Receiving Frequency
- Impedance
- Sensitivity
- Pick-up time
- Drop time
- All inputs must be used as clean contacts because the power is generated internally (secure power) to the
board and is set up to ensure compliance with double or reinforced insulation with regard to dangerous voltage.
- Any external circuits connected to the outputs of the control panel must be made in such a manner as to ensure
compliance with double or reinforced insulation with regard to dangerous voltage.
- All inputs are controlled by a programmed integrated circuit that performs a self check every time it starts
operating.
After having carried out the various connections and having supplied voltage, all the
LEDS are switched off.
The motor opens and closes, but it has no strength and moves slowly.
The gate opens but does not close after the time set.
The gate does not open or close by activating the various K, Radio, Open and Close
buttons.
The electric lock does not work.
LED DL1 blinks rapidly and no movement is activated.
ACCESSORIES -
LONG LEVER
The long lever is suggested for a leaf with a distance up to 500 mm
between the hinge of the leaf and the internal side of the pillar.
ELECTRIC LOCK
EN
433,92 MHz
52 Ω
>2,24 µV
300 ms
300 ms
FAULT
For the connections and the technical data of the optional equipments follow the relevant
handbooks.
code EAX2
BATTERY
Battery 2,2 Ah 12 V
code ZD04
T
ROUBLE SHOOTING
After having carried out all connections, by carefully following the layout and having positioned the gate in
intermediate position, check the correct ignition of red LEDS DL7, DL8 and DL9
In case of no ignition of the LEDS, always with gate in intermediate position, check the following and replace
any faulty components.
DL7 switched off Faulty photocells
DL8 switched off Faulty safety edge (In case the edge is not connected, carry out jumper between COM and
EDGE)
DL9 switched off Stop button malfunction (if Stop is not connected, perform the jump between COM and
STOP).
During functioning with personnel present, with DIP 1 at ON, check that during opening of M1 and M2 the green
DL2 and DL4 LEDS switch on and that during closing of M1 and M2 the red DL3 and DL5 LEDS switch on.
Or else, reverse the wires of the motor.
SOLUTION
Check fuses F1, FUSE 1.
If the fuse is blown, use only a suitable replacement.
F1 T 2A
TRANSFORMER PROTECTION FUSE (on the outside of the RS12
board)
FUSE 1 8A MOTOR PROTECTION FUSE
Check trimmers RUN and LOW-SPEED adjustment.
Make sure that the TCA trimmer is activated with LED DL6 on.
OPEN button always on, replace the OPEN control button or switch.
Sensor Auto test failed, check the connections between the control panel and the sensor power
supply.
Warning: If you are not using a power supply for the sensors, DIP 12 should be OFF.
Faulty safety edge contact. Faulty photocells contact with DIP 4 OFF.
Fix or replace the relative contact.
Ensure to have enabled DIP 8 at ON.
Place dip switches 1, 2 or 3 in the OFF position.
STRONG BOX FLAT
It is a strong metal (die-cast aluminium) container with lock to protect
manual release and/or push button. It is provided with a rocker switch and
unlocking device. It has to be fitted onto the wall.
In die-cast aluminium - IP54
BATTERY CHARGE CARD
code ZBA5
code EDP4
code ECB4
21