ADJUSTING THE FRONT FORK
a) COMPRESSION (LOWER ADJUSTER)
Standard setting: -16 clicks (± 1 click)
To reset standard calibration, turn adjuster screw (A)
clockwise to reach the fully closed position; then turn it
back by the mentioned clicks. In order to obtain a smooth
braking action, turn the adjuster counter clockwise. Vice
versa to obtain a harder braking action.
A
SPECIFICATIONS - OPERATION - MAINTENANCE
EN - 34
b) REBOUND (TOP ADJUSTER)
Standard setting: -10 clicks (± 1 click)
To reset standard calibration, turn adjuster (C) clockwise
to reach the fully closed position; then, turn it back by
the mentioned clicks. In order to obtain a smooth braking
action, turn the adjuster counter clockwise. Vice versa to
obtain a harder braking action.
C
D
c) BLEEDING (to carry out after each competition, or monthly).
Set the motorcycle on a central stand, release the fork
fully extended and loosen the air vent valve (D). Once
this operation is over, tighten the valve.
WARNING*: Never force the adjusting screws
beyond the maximum open and closed posi-
tions.