System message
Functions that are still
available
Er44
Motor blocked
None
(The control system
attempted to start up the
motor three times - 5 times
per attempt)
Er55
More than 960 cleaning
Manual cleaning
cycles in 48 hours
Automatic mode
Time-dependent cleaning
Er66
Switch element for rinsing
None
pump in the control system
overheated
Possible cause
Remedy
Filter drum rotating sluggishly or
Clean edge of the drum/drum seal and grease edge of the
jammed
drum Only use original OASE grease (order number
27872).
Ensure that the rollers move smoothly
Remove larger particles (e.g. snails, stones) from the
sprocket
The lips of the drum seal were
Disassemble the drum and ensure that the drum seal is
squeezed when the drum was installed.
positioned correctly during re-assembly
The drum load is distributed unevenly
Align the container horizontally
Temporary heavy soiling
Wait until the soiling decreases
Start-up phase of the filter system
This operating status is atypical. Avoid long-term operation
(e.g. during the first start-up)
in this state.
Fish are spawning
Pond heavily soiled
Clean the pond
Reduce the amount of soiling
Install the filter pump in an elevated position.
Screen elements heavily soiled
Clean the screen elements, descale ( Replacing screen
element)
Insufficient cleaning effect due to soiled
Clean nozzle
nozzle
Water level in the system too high:
Outlet pipes soiled
Clean outlet pipes
Outlet opening too small
Enlarge outlet opening
Max. flow rate exceeded
Reduce flow rate
A large amount of dirt has entered the
Clean foam filters
filter system, water is flowing over
(instead of through) the foam filters.
Control system is exposed to excessive
Protect the control system from heat
heat (sun, ambient temperature)
- EN -
Resetting the system
message
On|Off
Press
key for 5 s
On|Off
Press
key for 5 s
Automatic if the number of
cleaning procedures drops
below 960.
Automatic when cooled down
57