Ingersoll Rand 235G Manual Del Usuario página 3

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Ingersoll-Rand No. 50
Always use an air line lubricator with these tools.
We recommend the following Filter-Regulator-Lubricator
(FRL) Unit:
Model Handle
Drive
2
I.D.
Type
in
235G
pistol
1/2"
Tested in accordance with ANSI S5.1-1971 at free speed
Tested to ISO8662-1 loaded with frictionbrake to 9 RPM
Tested in accordance with ISO3744
When the life of the tool has expired, it is recommended that the tool be disassembled,
degreased and the parts be separated by material so that they can be recycled.
LUBRICATION
INSTALLATION
Main Line(s) Inner Ø
to be 3X Size of
Air Tool's Inlet Ø
To Air
System
To Air
Tool
Emergency
L
Shut-Off
Valve
Lubricator
Regulator
Drain Regularly
SPECIFICATIONS
Impacts Recommended
Torque Range
bpm
ft•lbs (N•m)
25 to 200
1,200
(34 to 271)
NOTICE
SAVE THESE INSTRUCTIONS. DO NOT DESTROY.
Inside USA use FRL unit #C28-04-FKG0-28
Outside USA use FRL unit #C28-C4-FKG0
After each eight hours of operation, unless the air line
lubricator is used, detach the air hose an inject about 1-1/
2 cc of oil into the Inlet Bushing (14).
After each forty-eight hours of operation, or as experi-
ence indicates, remove the Oil Chamber Plug (48) and fill
the impact mechanism oil chamber with the recom-
mended oil.
Branch Line(s) Inner Ø
to be 2X Size of
Air Tool's Inlet Ø
R
F
Filter
FRL
Compressor
(Dwg. TPD905-2)
Sound Level
Vibrations
dB (A)
Level
Pressure • Power
m/s
90.7
103.7
3
Inlet
Minimum
Connection
Inside Ø
(Thread)
(Air Hose)
2
NPT
inch (mm)
3.8
1/4
3/8 (10)
Tabla de contenido