D : INSTALLATION INSTRUCTIONS
D1-Position of the internal unit :
• The refrigerated air must be able to be diffused to each part of the room.
• The maximum height between the internal and external units is 5 m.
• Mount on a very stable wall to avoid vibrations.
• Avoid direct exposure to the sun.
• Make sure there is an easy evacuation for condensation.
• Do not cause interference with the remote control signal from a fluorescent lamp.
• Minimum distance between the air conditioner and household appliances (TV, radio etc.): 1 m
D2- Position of the external unit :
• Do not obstruct the airflow.
• Make sure that ventilation is adequate, minimize dust deposits, avoid exposure to the sun or rain.
• The noise of the apparatus working or the diffused air will not disturb the tranquillity of your neighbours.
• Mount the apparatus firmly on its support so as to reduce the noise and vibrations.
• Avoid positions close to potential inflammable gas leaks.
• The unit must be mounted firmly if it is installed high up.
• The unit must not be subjected to violent winds.
E : SPLIT SYSTEM INSTALLATION
E1- indoor i-unit support fixation :
• please respect minimal distances as indicated in global installation view.
• the support of indoor unit must be hold on a solid wall
• The support of indoor unit must be hold on the wall with at least 4 points to avoid vibrations
• Locate the holes and shoot.
• Hold the support with the screws