Optional Extras - BFT RIGEL 6 Instrucciones De Instalación

Centralita universal para controlar uno o dos motores
Ocultar thumbs Ver también para RIGEL 6:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 74
Logic
Definition
Configuration of
safety input SAFE 2.
SAFE 2
Configuration of
safety input SAFE 3.
SAFE 3
Configuration of
safety input SAFE 4.
SAFE 4
Configuration of
safety input SAFE 4.
SAFE 5
Configuration of
safety input SAFE 6.
SAFE 6
Configuration of
command input IC 1.
IC 1
Configuration of
command input IC 2.
IC 2
Configuration of
command input IC 3.
IC 3
Configuration of
command input IC 4.
IC 4
Configuration of the
1st radio channel
1ch
command
Configuration of the
2nd radio channel
2ch
command
Configuration of the
3rd radio channel
3 ch
command
Configuration of the
4th radio channel
4 ch
command
Configuration of
AUX 0
AUX 0 output. 20-21
Configuration of
AUX 1 output.
AUX 1
22-23
Configuration of
AUX 2 output.
AUX 2
24-25
Configuration of
AUX 3 output.
AUX 3
26-37
Type of lock.
LOCK
28-29
Fixed code
FIXED CODE
46
- RIgEL 6
INSTALLATION MANUAL
Cross out
Default
setting
used
3
6
4
74
5
2
6
77
7
4
8
79
9
0
79
10
11
12
6
13
84
14
0
0
1
61
2
4
3
62
4
2
5
64
3
6
65
0
0
1
2
3
4
9
5
6
7
2
8
9
10
5
11
0
6
1
2
3
3
4
5
6
1
7
8
9
10
11
0
12
13
14
15
0
0
1
0
0
1
Input configured as phot op test (tested photocell active during opening only).
Input configured as phot cl (photocell active during closing only).
Input configured as phot cl test (tested photocell active during closing only).
Input configured as Bar, safety edge.
Input configured as Bar, tested safety edge.
Input configured as Bar 8k2 (Inactive on SAFE 3,4,5,6).
Input configured as Bar Op, safety edge with inversion active only while opening. If while closing, the
movement stops.
Input configured as Bar Op TEST, safety edge tested with inversion active only while opening. If while
closing, the movement stops.
Input configured as Bar Op 8k2, safety edge with inversion active only while opening. If while closing, the
movement stops.
(Inactive on SAFE 3,4,5,6).
Input configured as Bar CL, safety edge with inversion active only while closing. If while opening, the
movement stops.
Input configured as Bar CL TEST, safety edge tested with inversion active only while closing. If while opening,
the movement stops.
Input configured as Bar CL 8k2, safety edge with inversion active only while closing. If while opening, the
movement stops.
(Inactive on SAFE 3,4,5,6).
Input configured as Start E.
Input configured as Start I.
Input configured as Open.
Input configured as Close.
Input configured as ped.
Input configured as Timer.
Input configured as Timer pedestrian.
Radio control configured as START E.
Radio control configured as Start I.
Radio control configured as Open.
Radio control configured as Close
Radio control configured as ped
Radio control configured as STOp
Radio control configured as AUx0 **
Radio control configured as AUx1 **
Radio control configured as AUx2 **
Radio control configured as AUx3 **
Radio control configured as ExpO1 **
Radio control configured as ExpO2 **
Output configured as monostable Radio Channel.
Output configured as SCA (gate open light).
Output configured as Courtesy Light command.
Output configured as Zone Light command.
Output configured as Stair Light
Output configured as Alarm
Output configured as Flashing light
Output configured as Latch
Output configured as Magnetic lock
Output configured as Maintenance
Output configured as Flashing Light and Maintenance.
Not used
Not used
Output configured as gate Status
Output configured as Bistable Radio Channel
Output configured as timed Radio Channel
Output configured as 12V
solenoid latch.
Output configured as 12V
magnetic lock.
Receiver is configured for operation in rolling-code mode.
Fixed-Code Clones are not accepted.
Receiver is configured for operation in fixed-code mode.
Fixed-Code Clones are accepted.

Optional extras

Hide quick links:

Tabla de contenido
loading

Tabla de contenido