Accessories; Magnetic Tape; Connector; Guided Magnetic Tape Position Measuring System - Balluff BML-S1F-A/Q-M0-0-KA/KD/KF Serie Manual De Instrucciones

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

BML-S1F_-A/Q _ _ _ -M_ _ 0- _ 0-...
Incremental Magnetic Linear Encoder
8

Accessories

Accessories are not included in the scope of delivery and
must be ordered separately.
8.1

Magnetic tape

When selecting the magnetic tape, make sure
the magnetic tape and sensor head are
compatible. This particularly applies to the
following factors:
Pole width (1 or 2 mm), see section 3.2.1
Reference points (none, one, two or more
(fixed periodic)), see section 3.3
For a complete technical description and assembly
instructions for magnetic tapes and rotative magnetic
tapes (magnetic rings), see the separate user's guides at
www.balluff.com/downloads-bml.
8.2

Connector

Permissible bending radius
Fixed routing
Moved
Cable material
Plug
Fig. 8-1:
M12 plug, 12-pin
For the pin assignment and colors, see Tab. 4-2
on page 12.
Type
BCC M41C-0000-1A-169-PS0C08-020-C009 BCC09MW
BCC M41C-0000-1A-169-PS0C08-050-C009 BCC09MY
BCC M41C-0000-1A-169-PS0C08-100-C009 BCC09MZ
BCC M41C-0000-1A-169-PS0C08-150-C009 BCC09N0
BCC M41C-0000-1A-169-PS0C08-200-C009 BCC09N1
For cable lengths ≥ 10 m, the controller for the A/B interface BML-S1F_...
1)
must be equipped with a protection circuit against surge (EN 61000-4-5).
Examples:
BCC M41C-0000-1A-169-PS0C08-020-C009 =
cable length 2 m
BCC M41C-0000-1A-169-PS0C08-050-C009 =
cable length 5 m
22
english
7.5 x outer diameter
15 x outer diameter
PUR
M12x1, 12-pin
~44
Ordering
code
8.3
Guided magnetic tape position measuring
system
Sensor guide consisting of a BML-R01-M_ _ _ aluminum
rail to hold the magnetic tape and a BML-C02
(BAM01MF) slide with gliders to guide the sensor head.
8.4

BDD counter

BDD 611-R3Q4-0-52-N-00 (BAE004K)
One-axis counter for all BML-S...
Min. edge distance code E, F, G, H, K, L, M, N, P, R
BDD 622-R3Q4-0-52-N-00 (BAE004M)
Two-axis counter for all BML-S...
Min. edge distance code E, F, G, H, K, L, M, N, P, R
BDD 632-R3Q4-0-52-N-00 (BAE004P)
Three-axis counter for all BML-S...
Min. edge distance code E, F, G, H, K, L, M, N, P, R
All counters need a 24 V DC operating voltage. A power
supply for rail mounting BAE PS-XA-1W-24-007-001
(BAE0001) is available for operation with 230 V.
1)
1)
1)
Tabla de contenido
loading

Este manual también es adecuado para:

Bml-s1f-a/q-m0-0-ka-s284 serieBml-s1f serie

Tabla de contenido