Cleaning And Maintenance; General Maintenance - ADURO P2 Manual De Usuario

Tabla de contenido
8.5 Alarm 5: Ignition failure
This alarm is triggered if the ignition phase fails, meaning that the minimum smoke temperature has not been
reached during the ignition phase.
8.6 Alarm 6: No pellets
This alarm is triggered if the smoke temperature falls below the minimum smoke temperature needed during
operation.
This alarm can also happen due to jamming of pellets of inadequate
dimensions.
8.7 Alarm 7: Thermal safety overheating
This alarm is triggered if the safety thermostat detects a temperature beyond 100°C.
8.8 Alarm 8: No negative pressure
This alarm is triggered if the external pressure sensor detects a pressure value below the pre-set limit.
All maintenance and cleaning of the stove should be carried out when the
stove is cold, and the power is disconnected.
Before using an ash vacuum cleaner make sure there are no embers left.

9.1 General maintenance

Glass
Soot and dust can easily be removed using a damp cloth that you dip in cold ash and rub on the sooty glass.
Special cleaning agents are also available to remove soot from the glass, e.g. the Aduro Easy Clean pad.
The pad neither scratches nor damages the glass, and it can be used multiple times. Water or other cleaning
agents are not necessary.
It is common maintenance to tighten the glass fittings shortly after the stove has been installed as well as to
check if the gaskets are properly placed.

9. Cleaning and maintenance

58
Tabla de contenido
loading