ADURO P2 Manual De Usuario página 57

Tabla de contenido
When an error occurs, the Alarm LED turns on and the stove automatically stops working.
The respective
alarm will show on the display for a certain time followed be the buzzer (if activated). The alarm
can be cleared by pressing and holding button 3. Whenever an alarm is cleared, the stove automatically enters
the final cleaning phase and shuts down completely for safety reasons. The Alarm LED will remain on and the
buzzer (if activated) will sound intermittently during the entire alarm phase. If the alarm is not cleared by
pressing button 3, the stove will initiate the final cleaning phase and the alarm message will remain on the
display.
The table below shows all 8 potential errors. Every error is explained in detail below.
Cause
Power outage
Smoke temperature sensor failure
Overheating
Exhaust fan failure
Ignition failure
No pellets
Thermal safety overheating
No negative pressure
8.1 Alarm 1: Power outage
When a power outage occurs during operation, there are two ways the stove may react.
If the period without power is shorter than the one set in the technician settings, the stove will continue its
operation once the power is on again.
If the period without power exceeds the pre-set limit, the stove will trigger alarm 1.
8.2 Alarm 2: Smoke temperature sensor failure
This alarm is triggered in case of a faulty smoke temperature sensor.
8.3 Alarm 3: Overheating
This alarm is triggered if the measured smoke temperature is beyond a certain value.
8.4 Alarm 4: Exhaust fan failure
This alarm is triggered in case of a faulty exhaust fan.
8. Potential errors
Display shows
AL 1 BLAC-OUT
AL 2 PROBE EXHAUST
AL 3 HOT EXHAUST
AL 4 FAN FAILURE
AL 5 NO LIGHTIN-
AL 6 NO PELLET
AL 7 SAFETY THERMAL
AL 8 FAILURE DEPRESS