Troubleshooting - Vimar RS09 Manual Para El Conexionado Y El Uso

Tarjeta con trimmer 230/120 vac para cancelas correderas
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 35
RS09/RS09.120
Operation with an encoder:
Obstacle detection
Description
During closing
The gate immediately reverses its movement, to open completely
During opening
The gate immediately reverses its movement for 1.5 seconds to then stop

9 - Troubleshooting:

Problem
The automatic gate system does not work
You cannot save the remote controls
The remote control does not work
You cannot enter travel programming
As soon as the gate starts it stops and reverses
During slowdown, the gate stops and reverses
The gate does not stop with the limit switches
tripping and obstacle detection trips
20
Cause
No mains supply
Blown fuses
Control and safety inputs not working
Safety devices open
Batteries of the remote control discharged
Remote control not compatible with the first
one saved
Reached memory saturation
Batteries of the remote control discharged
Safety devices open
Low acceleration on starting
Encoder not detected
Slowdown speed too low
The limit switch does not work properly
EN
Solution
Check the power line switch
Replace the fuses with others of the same value
Check the diagnosis leds (STOP, STPA and
PHOTO must be on)
Check the diagnosis leds (STOP, STPA and
PHOTO must be on)
Replace the batteries
The first saved remote control configures the
control panel to save only rolling-code remote
controls or only dip-switch remote controls
Delete at least one remote control or add an
external receiver (maximum capacity 128 remote
controls)
Replace the batteries
Check the diagnosis leds (STOP, STPA and
PHOTO must be on)
Increase the FORCE and SENS trimmer
Check the encoder connector is plugged in
Increase the Sldwn.sp. and Sens trimmer
Advance the limit switch bracket
Fig. 14