Briggs & Stratton Generac Generator Discount Parts Call 606-678-9623 or 606-561-4983
GENERAL
RECOMMENDATIONS
Regular maintenance will improve the performance and
extend the life of the generator. See any authorized dealer
for service.
The generator's warranty does not cover items that have
been subjected to operator abuse or negligence.To receive
full value from the warranty, the operator must maintain
generator as instructed in this manual.
Some adjustments will need to be made periodically to
properly maintain your generator.
All service and adjustments should be made at least once
each season. Follow the requirements in the "Maintenance
Schedule" chart below in Figure 14.
NOTE: Once a year you should clean or replace the spark
plug and replace the air filter. A new spark plug and clean
air filter assure proper fuel-air mixture and help your
engine run better and last longer.
GENERATOR
MAINTENANCE
Generator maintenance consists of keeping the unit clean
and dry. Operate and store the unit in a clean dry
Figure 14 – Maintenance Schedule
FILL IN DATES AS YOU
COMPLETE REGULAR SERVICE
MAINTENANCE TASK
Check oil level
Clean debris
Clean fuel valve
Change engine oil and oil filter
Service foam pre-filter
Service air filter
Service spark plug
Service spark arrester
Adjust valve clearance
Prepare for storage
¹
Change oil after the first (8) operating hours and every 100 hours or every year, whichever occurs first, thereafter.
Change sooner when operating under dirty or dusty conditions.
²
Replace more often under dirty or dusty conditions.
MAINTENANCE
SERVICE DATES
Before
Every 25
Every 50
Each Use
Hours or Yearly
Hours or Yearly
X
X
X
X²
X
If unit is to remain idle for longer than 30 days.
www.mymowerparts.com
environment where it will not be exposed to excessive
dust, dirt, moisture or any corrosive vapors. Cooling air
slots in the generator must not become clogged with snow,
leaves, or any other foreign material.
Check the cleanliness of the generator frequently and clean
when dust, dirt, oil, moisture or other foreign substances
are visible on its exterior surface.
NOTE: DO NOT use a garden hose to clean generator.
Water can enter the engine fuel system and cause problems.
In addition, if water enters the generator through cooling air
slots, some of the water will be retained in voids and cracks
of the rotor and stator winding insulation.Water and dirt
buildup on the generator internal windings will eventually
decrease the insulation resistance of these windings.
Generator Cleaning
Daily or before use, clean accumulated debris from
generator. Keep linkage, spring and controls clean. Keep area
around and behind muffler free from any combustible debris.
Inspect cooling air slots and openings on the generator.
These openings must be kept clean and unobstructed.
Generator parts should be kept clean to reduce the risk of
overheating and ignition of accumulated debris.
•
Use a damp cloth to wipe exterior surfaces clean.
•
Use a soft bristle brush to loosen caked on dirt, oil, etc.
Every 100 Hours
Every 100
or 6 months
Hours or Yearly
X
X¹
X
X
16
SERVICE DATES