be 12 mt.
TECHNICAL DATA.
- SPL 60/3
HP 50 PLASMA TORCH (6 mt.)
- SPL 90/3
- SPL 150/3
HPT 50 PLASMA TORCH (6 mt.)
SPL 60/3 PLASMA SOURCE OF
CURRENT
FOR CUTTING
- Electric protection
- Degree of casing protection :
- Thermic class of insulation
- Dimensions (mm)
- Mass (Kg)
- Torch included (model)
INPUT
1) Feeding voltage 3ph-50/60 Hz
- RANGE 1 - (Duty Cycle); X
Absorbed current
Power
Power factor
- GAMMA 2 - (Duty Cycle); X
Absorbed current
Power
Power factor
- Delayed power fuses
OUTPUT
- Loadless tension
- RANGE 1: (Duty Cycle) X
Conventional cutting tension
Conventional cutting current
Cutting capacity (carbon steel)
- RANGE 2: (Duty Cycle) X
Conventional cutting tension
Conventional cutting current
Cutting capacity (carbon steel)
NOTE (1)
400V voltage standard. See paragraph "CONNECTION TO
ELECTRIC NETWOTK" in order to make a change in power
supply.
MANUAL TORCH FOR HP PLASMA
CUTTING HP 50
- Gas used
- Compressed air pressure
- Total flow rate (for
Plasma and cooling)
- Striking system
- Cutting current
Data Cycle X = 60%
Data Cycle X = 100%
- Cutting mode in contact
with spacer
- Cable length
SPL 90/3 PLASMA SOURCE OF
CURRENT
:
Class I
IP 22
:
H
:
530x750x880
:
74 Kg
:
HP 50
(V)
230
400
(%)
90
90
(A) 18.6
10.8
(kW)
5.8
5.8
(cosphi) 0.79
0.79
(%)
35
35
(A) 29.5
17
(kW)
7.6
7.6
(cosphi) 0.65
0.65
A
16
10
(V)
231
(%)
90
(V)
95
(A)
30
(mm)
0.8 - 6
(%)
35
(V)
100
(A)
50
(mm)
2 - 15
:
dry compressed air
:
5 bar
:
140 L / min
:
HF and Pilot Arc
:
30 - 50A
:
50 A
:
40 A
:
GAMMA 1 (30A)
:
GAMMA 2 (50A)
:
6 m
FOR CUTTING
- Electric protection
- Degree of casing protection :
- Thermic class of insulation
- Dimensions (mm)
- Mass (Kg)
- Torch included (model)
INPUT
(1) Feeding voltage 3ph-50/60 Hz
- RANGE 1 - (Duty Cycle); X
Absorbed current
Power
Power factor
- GAMMA 2 - (Duty Cycle); X
Absorbed current
Power
Power factor
- Delayed power fuses
OUTPUT
- Loadless tension
- RANGE 1: (Duty Cycle) X
Conventional cutting tension
Conventional cutting current
Cutting capacity (carbon steel)
- RANGE 2: (Duty Cycle) X
Conventional cutting tension
Conventional cutting current
Cutting capacity (carbon steel)
NOTE (1)
400V voltage standard. See paragraph "CONNECTION TO
ELECTRIC NETWOTK" in order to make a change in power
supply.
MANUAL TORCH FOR HP PLASMA
CUTTING HP 150
- Gas used
- Compressed air pressure
- Total flow rate (for
Plasma and cooling)
- Striking system
- Cutting current
Data Cycle X = 60%
Data Cycle X = 100%
- Cutting mode
in contact
with spacer
- Cable length
SPL 150/3 PLASMA SOURCE OF
CURRENT FOR CUTTING
- Electric protection
- Degree of casing protection :
- Thermic class of insulation
- Dimensions (mm)
- Mass (Kg)
- Torch included (model)
INPUT
(1) Feeding voltage 3ph-50/60 Hz
- 17 -
:
Class I
IP 22
:
H
:
530x750x880
:
94 Kg
:
HP 150
(V)
230
400
(%)
75
75
(A)
38
22
(kW) 12.6
12.6
(cosphi) 0.84
0.84
(%)
35
35
(A)
55
32
(kW) 15.5
15.5
(cosphi)
0.7
0.7
A
32
20
(V)
235
(%)
75
(V)
125
(A)
60
(mm)
3 - 18
(%)
35
(V)
135
(A)
90
(mm)
5 - 25
:
dry compressed air
:
5 bar
:
220 L / min
:
HF and Pilot Arc
:
/ A
:
150 A
:
/
:
GAMMA 1 (60A)
GAMMA 2 (90A)
:
6 m
:
Class I
IP 22
:
H
:
530x750x880
:
121 Kg
:
HP 150
(V)
230
400