Mitsubishi Electric Mr.SLIM PKA-A12GA Manual De Instalación página 9

Ocultar thumbs Ver también para Mr.SLIM PKA-A12GA:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

6.
Electrical work
6.1.3. K-control application
The
following
connection
patterns
are available.
The
outdoor
unit power
supply
patterns
vary
on models.
<For cooming onmy modems>
<For heat pump modems>
©
®
©
@
®
®
@
@
(_) Outdoor
unit power supply
(_) Wiring circuit breaker or isolating
switch
C-C} Outdoor
unit
(_) Indoor unit/outdoor
unit connecting
cords
Remote
controller
(Only for PKA-A.GA)
(_ Indoor unit <For heat pump models>
(G'_ Indoor unit <For cooling only models>
(_ Indoor unit power supply
Set the DIP switch of the indoor
unit control board.
SW5
1
2
3
SW5-1
:ON
SW5-2, 3 : OFF
Set the DIP switch of the indoor
unit control board.
SW5
1
2
3
SW5-1,2
:ON
SW5-3
: OFF
* Affix a label B that is included with the manuals near each wiring diagram for the indoor and outdoor units.
<For heat pump models>
<For cooling
only models>
_) Outdoor unit power supply
.
©
@
@
©
@
@
@
Set the DIP switch of the indoor
unit control board.
©
Main indoor
(_)
Sub indoor
123
1123
I
SW5
SW5-1 : ON
SW5-1
: ON
SW5-2 : OFF
SW5-2
: OFF
SW5-3 : OFF
SW5-3
: ON
@
Set the DIP switch of the indoor
unit control board.
(_
Main indoor
(_
Sub indoor
1 23
1 23
I
SW5
SW5-1
: ON
SW5-1 : ON
SW5-2
: ON
SW5-2 : ON
SW5-3
: OFF
SW5-3 : ON
(_) Wiring circuit breaker or isolating
switch
C-C} Outdoor
unit
(_) Indoor unit/outdoor
unit connecting
cords
_E_Remote
controller
(Only for PKA-A.GA)
(_ Main indoor unit <For heat pump models>
(G'_ Sub indoor unit <For heat pump models>
(_ Indoor unit power supply
(_) Main indoor unit <For cooling only models>
Sub indoor unit <For cooling only models>
* Affix a label B that is included with the manuals near each wiring diagram for the indoor and outdoor units.
To change to K-control,
set the DIP switch (SW5) of the indoor unit control board as
shown in the above figure and change the electric wiring of the indoor unit as shown
in the right figure.
Set up Dip switch after turning
off Power supply switch.
Be careful that setting
the DIP switch (SW5) of the indoor unit control board varies
between the heat pump models and cooling models of the outdoor unit.
DIP
switch
(SW5)
OFF
ON
SW5-1
A_CONTROL
K-CONTROL
SW5-2
heat pump models
cooling only models
_ Dip switch SW5-2 and SW5-3 is effective only
sw5-3
MAIN
SUB
_Jwhen Dip switch SW5-1 (K-CONTROL) is ON.
* There
are three
types
of labels
(labels
A, B, and
C). Affix
the appropriate
labels
to
the units
according
to the wiring
method.
Indoor unit model
PKA
Indoor unit power supply
Single 208/230 V, 60 Hz
Minimum
circuit ampacity
1 A
Maximum
rating of overcurrent
protective
device
15A
Indoor unit power supply
2 x Min. AWG16
-_
Indoor unit power supply earth
1 x Min. AWG16
×
H/P: 3 x AWG22 (polar)
_;_
C/O: 2 x AWG22
(polar)
Indoor unit-Outdoor
unit
"1
Indoor unit earth
Remote controller-Indoor
unit
*2
2 x AWG22 (Non-polar)
Indoor unit L1-L2
*3
AC 208/230 V
# _
Indoor unit-Outdoor
unit $1-$2
*3
DC12 V
E "_
Indoor unit-Outdoor
unit $1 -$3
*3
D012 V
_5
Remote controller-Indoor
unit
*3
DC12 V
41. Max. 50 m, 185 ft
42. The 10 m, 30 ft wire is attached
in the remote controller
accessory.
Max. 500 m, 1500 ft
43. The figures are NOT always against the ground.
Notes:
1. Wiring
size must comply
with the applicable
local and national code.
2. Use copper
supply
wires.
3. Use wires rated 300V or more for the power supply
cables.
4. mnstamm an earth
monger than other cabmes.
Connectors
INDOOR UNIT
CONTROL BOARD
To change to the K-control,
make sure to change the
INDOOR UNIT
CONTROL BOARD
9

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Mr.slim pka-a18gaMr.slim pka-a12galMr.slim pka-a18gal

Tabla de contenido