First
Second
code
code
Setting name
9
Automatic temperature compensation
00
Leaving water temperature compensation value
01
Domestic hot water tank compensation value
02
Thermo ON/OFF admission
A
Option setup
00
Current limitation.
01
Not applicable. Do not change the default value.
02
Set point: required temperature difference for
leaving and returning water
03
Set point: multiple set point 1 required temperature
value
04
Set point: multiple set point 2 required temperature
value
b
Domestic hot water set points
00
Set point: reheat minimum temperature
01
Set point: reheat maximum temperature
02
Status: weather dependent domestic water
heating
03
Set point: storage temperature
04
Automatic maximum domestic hot water storage
temperature
C
Leaving water temperature limits
00
Set point: leaving water maximum temperature
01
Set point: leaving water minimum temperature
02
Not applicable. Do not change the default value.
03
Not applicable. Do not change the default value.
d
Domestic water heating retention times
00
Set point: minimum time for domestic water
heating
01
Set point: maximum time for domestic water
heating
02
Set point: interval minimum stop time of domestic
water heating
E
Service mode
00
Vacuum mode
01
Not applicable. Do not change the default value.
02
Not applicable. Do not change the default value.
03
Not applicable. Do not change the default value.
04
Pump only operation
Installation manual
33
Installer setting at variance with default value
Date
Value
Date
Default
Value
value
Range
0
–2~2
0
–5~5
0
–5~5
0
0~2
0
0~2
10
5~15
35
25~80
65
25~80
35
35~65
45
35~75
1 (ON)
0/1
70
45~75
70
55~75
80
37~80
25
25~37
20
18~22
5
5~18
10
5~20
30
10~60
15
5~30
0
0/1
0 (OFF)
0/1
0 (OFF)
0/1
1
0~2
0
0~2
RKHBRD011~016ABV1+Y1
Indoor unit for air to water heat pump system
4PW61218-1C – 2012.06
Step
Unit
0.2
°C
0.5
°C
0.5
°C
1
—
1
—
1
°C
1
°C
1
°C
1
°C
1
°C
—
—
1
°C
1
°C
1
°C
1
°C
1
°C
1
°C
1
—
5
—
5
—
—
—
—
—
—
—
1
—
1
—