Vimar SL230.T Manual De Instrucciones Para La Conexión Y El Uso página 20

Tarjeta de mando dip 230/120 vca para cancelas correderas
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 50
SL230.T - SL230.T.120
Connecting sensitive edge and/or internal photocells.
With DSW2 Dip switch 1 OFF, programmable input SOP is configured as normally closed for the use of a non-resistive sensitive edge N.C. With the
sensitive edge not engaged LED DL6 must be on. If not used, jumper between COM and SOP.
With DSW2 Dip switch 1 ON, programmable input SOP is configured for the use of a resistive sensitive edge 8K2. With the sensitive edge not engaged
LED DL6 must be on. If not used,
The triggering of input SOP, during closing, inverts and immediately stops motion. After the edge is disengaged, the gate remains still until a new control
is given. The triggering of input SOP, during opening, inverts and immediately stops motion. After the edge is disengaged, gate closing motion resumes.
Edge with
electro-
mechanical
switch
Electrical connection with Photo-test function active
With DSW1 Dip switch 8 ON, programmable input P.OUT controls the operation of the safety devices.
Internal
photocell
20
set DSW2 Dip switch 1 to OFF and jumper between terminal COM and SOP.
DSW2
DIP 1 OFF
External
Internal
photocell
photocell
Resistive edge
8.2 kOhm
External
photocell
Safety device when closing N.C.
EN
DSW2
DIP 1 ON
Safety device when
opening and closing N.C.
Accessories +24VDC
Accessories -24VDC
Safety test +24VDC