Input wiring.
The control unit is supplied with non-jumpered normally closed safety inputs (P.IN, STOP, SCL, SOP).
Add a jumper between the common (COM) and the input you do not intend to use. LEDs DL1 DL3 DL5 and DL6 must be on.
OPENING AND CLOSING SAFETY DEVICE N.C.
SEQUENTIAL/START N.O.
SAFETY DEVICES WHEN CLOSING N.C.
SENSITIVE EDGE SAFETY N.C.
LEFT LIMIT SWITCH N.C.
RIGHT LIMIT SWITCH N.C.
+24VDC ACCESSORIES
-24VDC ACCESSORIES
+24VDC 2nd RADIO CHANNEL PULSE
+24VDC LIGHT 2W MAX
Connecting control push buttons and keyswitch.
The contacts are normally open. Input SEQ (LED DL2) controls the opening or complete closing of the gate. Input PED (LED DL4) controls the opening
or partial closing of the gate. LEDs DL2 or DL4 and LED DL.S light up when the keyswitch or push buttons connected in parallel are operated.
18
STOP N.C.
PEDESTRIAN N.O.
COMMON (NEGATIVE)
N.O.
N.C.
OPENING/CLOSING SAFETY DEVICE N.C.
SEQUENTIAL/START N.O.
SAFETY DEVICES WHEN CLOSING N.C.
SENSITIVE EDGE SAFETY 8K2
DSW2
DIP 1 OFF
RIGHT LIMIT SWITCH N.C.
DSW1
DIP 8 OFF
Button controlling
SEQ
Button controlling
PED
N.C. N.O.
EN
STOP N.C.
PEDESTRIAN N.O.
LEFT LIMIT SWITCH N.C.
COMMON (NEGATIVE)
+24VDC ACCESSORIES
-24VDC ACCESSORIES
+24VDC SAFETY TEST
+24VDC LIGHT 2W MAX
DSW2
DIP1 ON
DSW1
DIP 8 ON