Interval
Inspection/maintenance
➤ Change the oil.
In the first
month or after
➤ Check the air filter ("Servicing the air filter (fig. 7, page 5)" on
20 hours.
➤ Check the air filter ("Servicing the air filter (fig. 7, page 5)" on
Every 3 months
or after
50 hours.
➤ Change the oil.
Every 6 months
or after
➤ Check the spark plug ("Servicing the spark plugs" on
100 hours.
➤ Check the valves.
Once a year or
every 300 hours
➤ TEC29 only: Check the fuel tank and fuel filter.
➤ Check the vibration damper.
Every two years ➤ TEC29 only: Check the petrol supply lines.
➤ TEC29LPG only: Check the gas supply lines.
10.2

Preparing maintenance work

CAUTION!
!
Note the following for all maintenance work:
 The generator must not be running.
 All the parts must be cooled down.
➤ Switch the generator to no function with the main switch (fig. 4 1,
page 4).
➤ Disconnect the positive terminal of the supply battery.
➤ Open the generator flap.
For maintenance work, you can take the generator out (fig. 5, page 4):
WARNING!
!
The mounting plate with generator is very heavy (> 40 kg) and
could fall out the housing if you take it out too far.
➤ Undo the fastening screws (1).
➤ Remove the mounting plate (2) with the generator from the housing (3).
EN
page 49).
page 49).
page 50).
Servicing the generator
47